Power Cable; Fuse - Extreme Networks Alpine 3804 Hardware Manual

Extreme alpine 3804: hardware guide
Hide thumbs Also See for Alpine 3804:
Table of Contents

Advertisement

Safety Information
• The unit must be connected to a grounded outlet to comply with European safety standards.
• The socket outlet must be near the unit and easily accessible. You can only remove power from the
unit by disconnecting the power cable from the outlet.
• This unit operates under Safety Extra Low Voltage (SELV) conditions according to the IEC 950
standard. The conditions are only maintained if the equipment to which it is connected also operates
under SELV conditions.
• The appliance coupler (the connector to the unit and not the wall plug) must have a configuration
for mating with an EN60320/IEC320 appliance inlet.
• France and Peru only
This unit cannot be powered from IT† supplies. If your supplies are of IT type, this unit must be
powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary connection point
labeled Neutral and connected directly to ground.

Power Cable

Use an AC power cable appropriate for your country. Check your local electrical codes and regulatory
agencies for power cable requirements. The countries listed below have the following additional
requirements:
• USA and Canada
— The cable set must be UL-listed and CSA-certified.
— The minimum specification for the flexible cable is No. 18 AWG (1.5 mm
3-conductor.
— The cable set must have a rated current capacity of at least the amount rated for each specific
product.
— The AC attachment plug must be an Earth-grounding type with a NEMA 5-15P (10 A, 125 V)
configuration.
• Denmark
— The supply plug must comply with section 107-2-D1, standard DK2-1a or DK2-5a.
• Switzerland
— The supply plug must comply with SEV/ASE 1011.
• Argentina
— The supply plug must comply with Argentinian standards.
NOTE
When using dual power supplies, make sure that each AC power supply attaches to an independent
power source.

Fuse

This information only pertains to the Summit series of switches, with the exception of the Summit7i.
The unit automatically adjusts to the supply voltage, and it is suitable for both 110 VAC and 200-240
VAC operation.
To change the fuse in a Summit series switch: