Table 98 describes the immunity standards for the 10GLRi module.
Table 98: Immunity standards for the 10GLRi module
Test
Immunity to
electrostatic
discharge
Immunity to
radiated RF electric
fields
Immunity to fast
transients
Immunity to power
surges
Immunity to RF
common mode
Power-frequency
magnetic field
Mains voltage dips
Voltage
interruptions
Immunity to
radiated RF field.
Keyed carrier
Performance criteria follows:
• A—Unit continues to function with maximum of 10% traffic loss, 10% CRC errors during the
application of interference and recovers without operator intervention.
• B—Unit continues to function after the test without operator intervention.
• C—Temporary loss of function is permitted, provided the function is self-recoverable or can be
recovered by the operation of controls
Table 99: F48Ti and F96Ti module specifications
Physical Dimensions
Safety
Extreme Networks Consolidated Hardware Guide
Test Specification
Standard
(CE required)
EN 61000-4-2
±8kV air discharge,
±4kV contact discharge
EN 61000-4-3
80-1000 MHz, 3V/m,
80% AM (1kHz)
EN 61000-4-4
Data lines: ±0.5kV
Power lines: ±1kV
EN 61000-4-5
±1kV line to line, ±2kV
line to earth
EN 61000-4-6
150kHz-80MHz 3V
RMS 80% AM (1kHz)
EN 61000-4-8
50Hz, 1A/m RMS
EN 61000-4-11
30% reduction for 10mS
60% reduction for
100mS
EN 61000-4-11
>95% for 5000mS
ENV 50204
900MHz±5MHz 3V/m,
50% duty cycle, 200Hz
replicating frequency
Height: 1.6 inches (4.1 cm)
Width: 15.1 inches (38.4 cm)
Depth: 16.0 inches (40.6 cm)
Weight: 6.25 lbs (2.81 kg)
Performance
Criterion
Test
(CE required)
Specification
B
±15kV air
discharge, ±8kV
contact
discharge
A
80-1000 MHz,
10V/m, 80% AM
Modulation
(1kHz)
B
-
B
-
A
-
A
-
B
-
C
-
C
-
A
-
BlackDiamond Modules
Performance
Criterion
B
A
B
A
A
A
A
B
B
A
317