Using the Memory Address Map
- Module startup register
This register holds the module operating status.
The CNT24-2(FIT)GY does not contain a module shutdown function. Therefore,
the fact that the module is shut down simply indicates that the module has not been
started.
- Error status
This register stores the error status of the module.
The error status register is reset when the module is restarted.
Conflicting setting (32h) is an error status that indicates that the module was started
using settings that are invalid for the
CNT24-2(FIT)GY. When a setting conflict is generated, the module remains shut
down. To resolve the problem, see the settings in "Function", "Counter Input
Multipliers", and "Clear Signal Synchronization Settings".
62
00h: Module shutdown
01h: Module operating
00h: Normal
32h: Conflicting settings
CNT24-2(FIT)GY