Contec F&eIT Series User Manual page 64

Isolated counter module
Hide thumbs Also See for F&eIT Series:
Table of Contents

Advertisement

Counting direction
This item specifies the direction in which counting is to be performed.
Phase A DOWN
/counterclockwise
Phase A UP
/clockwise
Clear Signal Input Logic
Selecting clear signal (phase Z) input logic
Setting the Clear Signal Operation
This item specifies the operation of clear signal (phase Z) input
- Clear signal input disabled
Z-phase input
Counter
- Enabled only for one-time input of the next clear signal
Z-phase input
Counter
- Enabled for all clear signal input operations
Z-phase input
Counter
Figure 5.8.
Note!
When not using the clear signal (phase Z) option, choose the " C lear signal input
disabled" setting.
Preset count values
Entering the value allows the counter value to be set as a preset value.
The function works only when the value is set in this area only.
CNT24-2(FIT)GY
00h: Phase A down/counterclockwise
01h: Phase A up/clockwise
Counting
Mono-phase counter
direction
Counts DOWN on
phase A input; counts
UP on phase B input.
Counts UP on phase A
input; counts DOWN on
phase B input.
00h: Positive logic (HIGH active)
01h: Negative logic (LOW active)
01h: Clear signal input disabled
02h: Enabled only once for the next clear signal input
03h: Enabled for all clear signal input operations
0
Ignored
Start
0
0
Start
0
0
Setting a Clear Signal Operation
(Clear Signal Input Logic = 00h)
2-phase counter
Counts DOWN when
the rotary encoder
rotates clockwise.
Counts UP when the
rotary encoder rotates
clockwise.
Ignored
Ignored
Ignored
Ignored
0
0
Using the Memory Address Map
Mono-phase counter
with gate control
Counts DOWN on
phase A input with
phase B being HIGH.
Counts UP on phase A
input with phase B
being HIGH.
Ignored
Ignored
0
59