Agilent Technologies 5517B Operation And Service Manual page 95

Laser head
Hide thumbs Also See for 5517B:
Table of Contents

Advertisement

Pin
U1
1
41A5
2
0000
3
8816
4
F9C3
5
UA4P
6
CCPC
7
0000
8
27HH
9
6678
10
0P7C
11
4UHP
12
7U30
13
3P95
14
41A5
15
NC
16
NC
NC A3U1-3, A3U5-6, and A3U19 are 14-pin package configuration.
u. If ending troubleshooting procedures at this point, disconnect power from HP5517B/C/D Laser Head, set all test
jumpers to their left-most (normal) positions, and replace laser head front panel and side covers.
8-139. Photodiode and Amplifier Troubleshooting
8-140. This procedure assumes that the power supplies are functioning properly. Use a dedicated digital voltmeter.
Do not use the signature analyzer's voltmeter function.
A TILDE ("-") PRECEDING ALL SIGNALS INDICATES NEGATIVE-TRUE LOGIC.
a. Set HTR OK jumper to LO, PHOTO DIODE jumper to TEST, and LIQUID CRYSTAL jumper to PASS.
Is voltage at A3TP16 more negative than-4V? If no, go to step c. If yes, go to step b.
b. Set LIQUID CRYSTAL jumper to ACT. Is voltage at A3TP16 more positive than -1V? If no, go to step
c. If yes, go to step d.
c.
Verify that A3U11 (Pin 13) is 0V ±10 mV. If not, replace A3U11. With LIQUID CRYSTAL jumper still
set to PASS, verify that voltage at A3TP16 is 6/11 of that at A3U11 D (Pin 14) and voltage at junction
of resistors A3R20 - A3R22 is 1/11 of that at A3U11D (Pin 14). If not, check A3R6, R1 7, R20, R22,
and R24. Also, A3U12A or A3U12D may be incorrectly loading this node.
d. Amplifier is OK. Check photodiode. Verify that laser beam is on. Set PHOTO DIODE jumper to
NRM. Measure A3TP16 voltage. If it is >+0.5 V then photodiode A4CR1 is good. If it is
approximately -6 V then either the photodiode is shorted or A3U11 is bad. If it is between -0.5 V and
+0.5 V, go to step e.
e. Remove PHOTODIODE jumper and check for diode action between the left hand pin of the jumper
and ground, if diode action is not observed, replace A4CR1. If diode action seems OK, maybe the
problem is caused by not enough light reaching the photodiode. Remove the A6 Sampler Assembly
and inspect the liquid crystal, beam splitters and A4CR1 for dirt, scratches, etc. If O.K., see Liquid
Crystal Troubleshooting.
Table
Table
U2
113
4UHP
CCPC
7U30
41A5
■ 41A5
, FP96
4 A3 9
41A5
41A5
FP96
4 A3 9
8U33
0000
0000
7130
3P95
8U33
7U30
6678
41A5
538U
20H3
F9C3
FP96
41A5
CCPC
41A5
41A5
NC
NC
NC
NC
8-4.
Signature
U4
U5
6678
4CCA
0000
FP96
8A5F
P861
0000
4UHP
20H3
P861
FP96
4H86
UA4P
0000
0000
41A5
6678
41A5
A0H0
41A5
4 A3 9
88F5
A5P7
0000
P861
538U
0P7C
0000
41A5
4UHP
NC
41A5
NC
NOTE
U6
U8
41A5
CCPC
F9C3
0000
41A5
F09F
27HH
CU8C
0000
267H
41A5
4 A3 9
9CHA
UA4P
0000
0000
4UHP
C5U7
4CCA
CC8F
0P7C
FF57
41A5
0000
C5U7
9CHA
0P7C
CCPC
41A5
41A5
NC
NC
NC
NC
1119
8816
7130
xxxx
3721
0000
0000
41A5
3721
7U30
0000
41A5
NC
NC