Battery Charge Indicator; System Fault Indicator; Alarm; Indoor/Outdoor Operation Indicator - JLG R4045 Operation And Safety Manual

Hide thumbs Also See for R4045:
Table of Contents

Advertisement

SECTION 3 - MACHINE CONTROLS, INDICATORS AND OPERATION

Battery Charge Indicator

The battery charge indicator displays the current
charge status of the onboard batteries. RED LED
flashing = batteries depleted, RED LED ON solid =
batteries low, RED LED ON and GREEN LEDs ON =
batteries FULL charge.

System Fault Indicator

When this indicator light is flashing, a system fault
has occurred, possibly stopping machine opera-
tion.
Check the MDI Indicator (if equipped) on the
Ground Control Station to see if a DTC is dis-
played.
If the code cannot be cleared by the operator, the
machine will require service by a qualified JLG
mechanic.

Alarm

This alarm mounted on the front of the platform control station will
sound for various machine conditions or warnings such as, system
ready chirp or if the machine tilt warning is activated.
3-14

Indoor/Outdoor Operation Indicator

The Indoor (GREEN) indicator and the Outdoor
(YELLOW) indicator displays which mode the
machine is currently set to operate in.

Indoor/Outdoor Operation Mode Switch

This button will toggle between the indoor/
outdoor operation modes.

Low/High Drive Speed

The two position speed switch controls high or
low range drive speed. High speed would be
used in unobstructed open, flat, and level work
areas. Low speed would be used in close work
areas with obstacles, other machinery or per-
sonnel to avoid.
NOTE:
Drive speed will automatically be
reduced to low drive when the platform is raised above the
stowed position, regardless of speed switch position.
Mobile Phone Cradle (If Equipped)
Provides an enclosed area for mobile phones in the platform.
USB Port (If Equipped)
Provides a USB port in the platform.
31215942

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents