Eagle Performance - Battery Charger; Battery Maintenance And Safety Practices - JLG R4045 Operation And Safety Manual

Hide thumbs Also See for R4045:
Table of Contents

Advertisement

SECTION 6 - GENERAL SPECIFICATIONS AND MAINTENANCE

Eagle Performance - Battery Charger

1
1. AC Voltage Input Cable
• Battery Type Indicator: Yellow LED on
• Battery Charging: 30%-60%-90% Red LED on
• Charge Complete: Green LED on
• No Battery Detected: 30% Red LED blinking
• Overall Timer Shutdown: 30-60-90% Red LEDs blinking
• Internal OverTemp Shutdown: 30 - 90% Red LEDs blinking
6-14
2. Charge Indicator LEDs

Battery Maintenance and Safety Practices

NOTE:
These instructions are for unsealed (wet) batteries only.
If machine is equipped with sealed batteries, no maintenance
other than cleaning corroded battery terminals is required.
ENSURE THAT BATTERY ACID DOES NOT COME INTO CONTACT WITH SKIN OR CLOTHING.
WEAR PROTECTIVE CLOTHING AND EYEWEAR WHEN WORKING WITH BATTERIES. NEU-
TRALIZE ANY BATTERY ACID SPILLS WITH BAKING SODA AND WATER.
BATTERY ACID RELEASES AN EXPLOSIVE GAS WHILE CHARGING, ALLOW NO OPEN FLAMES,
SPARKS OR LIGHTED TOBACCO PRODUCTS IN THE AREA WHILE CHARGING BATTERIES.
CHARGE BATTERIES ONLY IN A WELL VENTILATED AREA.
ADD ONLY DISTILLED WATER TO BATTERIES. WHEN ADDING DISTILLED WATER TO THE
BATTERIES, A NON-METALLIC CONTAINER AND/OR FUNNEL MUST BE USED.
31215942

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents