B. Wiring Requirements
IntelliFire™ Plus Ignition System Wiring
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.2, IPI Wiring Diagram.
• This appliance is equipped with an IntelliFire™ Plus
control valve which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the unit OR install 4 AA cell
batteries (not included) into the battery pack before use.
NOTICE: Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Battery polarity must be correct when installing batteries.
Do not store batteries in the battery pack when the
appliance is powered by the 6 volt transformer connected
to permanent electrical service.
TO JUNCTION
BOX (110V)
Figure 8.2 IPI Plus Wiring Diagram
Majestic • DBDV36PLATIN, DBDV36PLATIL, DBDV42PLATIN, DBDV42PLATIL Installation Manual • 2454-980 Rev. F • 5/17
FLAME
SENSE
MODULE
I
S
FLAME
MODULATION
IGNITOR
RC100
(OPTIONAL WIRELESS REMOTE CONTROLS)
BATTERY PACK
6V DC
RED
THERMOSTAT WIRE
BLK
ASSEMBLY / WALL
SWITCH WIRE
RC200
RC300
45