Majestic DBDV36PLATIN Installation Manual page 46

Hide thumbs Also See for DBDV36PLATIN:
Table of Contents

Advertisement

Wall Switch Installation for Fan (Optional)
If the box is being wired to a wall mounted switch for use
with a fan (See Figure 8.3):
• The power supply for the appliance must be brought into
a switch box.
• The power can then be supplied from the switch box to
the appliance using a minimum of 14-3 with ground wire.
• At the switch box connect the black (hot) wire and red
(switch leg) wire to the wall switch as shown.
• At the appliance connect the black (hot), white (neutral)
and green (ground) wires to the junction box as shown.
• Add a 1/4 in. insulated female connector to the red (switch
leg) wire, route it through the knockout in the face of the
junction box, and connect to the top fan switch connector
(1/4 in. male) as shown.
46
Majestic • DBDV36PLATIN, DBDV36PLATIL, DBDV42PLATIN, DBDV42PLATIL Installation Manual • 2454-980 Rev. F • 5/17
Minimum 14-3 AWG
with Ground
Junction Box
Red
Figure 8.3. Junction Box Wired to Wall Switch
Switch
Red
Black
Black
White
White
Green
Green
Power
Switch Box
Supply
Wires
Knockout

Advertisement

Table of Contents
loading

Table of Contents