B. Wiring Requirements
IntelliFire Touch
Ignition System Wiring
®
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IFT controlled appliance junction box to a switched circuit.
Incorrect wiring will override IFT safety lockout.
• Refer to Figure 8.3 or 8.4, IFT Wiring Diagram.
• This appliance is equipped with an IntelliF___ire Touch
control valve which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the unit OR install 4 AA cell
batteries (not included) into the battery pack before use.
IFT-RC400
REMOTE
CONTROL
RF MODULE
Figure 8.3 IFT Wiring Diagram
34
FLAME
IGNITER
SENSE
ADAPTER
S
I
Order separately for Heat-Zone connection
6 PIN
EMBER BULBS (1-4)
BLK
BRN
ACCENT LIGHT #1
BRN
BLK
JUMPER WIRE
RED
Majestic • MARQ42STIN Installation Manual • 2272-980 Rev. H • 4/21
NOTICE: Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Battery polarity must be correct when installing batteries.
When using batteries as a power source, the 6-volt
transformer must be unplugged from the receptacle.
Do not store batteries in the battery pack when the
appliance is powered by the 6 volt transformer connected
to permanent electrical service.
TO JUNCTION
BOX 110-120
VAC
(OPTIONAL HEAT-ZONE LOCATION)
2005-021
WIRE PLUG ASSEMBLY
ACCENT LIGHT #2
POWER VENT
ACCESSORY CABLE
(OPTIONAL)
BRN
RED

Advertisement