B. Wiring Requirements
IntelliFire Touch
Ignition System Wiring
®
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.4, IntelliFire Touch Wiring Diagram.
• This appliance is equipped with an IntelliFire Touch
control valve which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the unit OR install 4 AA cell
batteries (not included) into the battery pack before use.
Figure 8.4 IntelliFire Touch
Majestic • MER36N, MER36L, MER42N, MER42L Installation Manual • 2595-980 Rev. B • 5/23
IFT-RC400
FLAME
SENSE IGNITER
REMOTE
CONTROL
IFT-RC150
IFT-ECM MODULE
WIRELESS
2326-130
WALL SWITCH
(OPTIONAL)
(OPTIONAL) RF MODULE
2326-120
IFT-ECM MODULE
2326-130
IFT-WFM
WIFI MODULE
(OPTIONAL
APPLIANCE
ON/OFF
CONTROL
(OPTIONAL)
Wiring Diagram
®
NOTICE: Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Battery polarity must be correct when installing batteries.
When using batteries as a power source, the 6-volt
transformer must be unplugged from the receptacle.
Do not store batteries in the battery pack when the
appliance is powered by the 6 volt transformer connected
to permanent electrical service.
6 VAC
TRANSFORMER
TO JUNCTION
BOX 110-120 VAC
(OPTIONAL)
IFT-ACM MODULE
2326-150
BLK
RED
USB-C WIRE
HARNESS
2326-222
BLK
BRN
JUNCTION BOX
110-120 VAC
2326-013
GFK-160A FAN
(OPTIONAL)
3 PRONG 110VAC
FAN
6V DC
BATTERY PACK
2326-142
RED
BLK
59