4. Error messages relating to CC-Link
12.11 : CC-Link communication error
Chapter
12.12 : CC-Link overtime error
4
12.70 : Incorrect option setting
4-8
Code
: &H0C0B
Meaning/Cause : a. Error in cable for CC-Link system.
b. Master station sequencer power is turned off or the
operation has stopped.
Action
: 1. Check for the cable and take measures to suppress noise
on the controller.
2. Check if the master station sequencer is operating
correctly.
Code
: &H0C0C
Meaning/Cause : a. Communication error in CC-Link system due noise, etc.
b. Master station sequencer power is turned off or the
operation has stopped.
Action
: 1. Take measures to suppress noise on the CC-Link system
cable and controller.
2. Check if the master station sequencer is operating
correctly.
Code
: &H0C46
Meaning/Cause : a. Error in DIP switch setting on option unit.
b. Mismatched option units have been installed.
c. Cannot identify the installed option unit.
Action
: 1. Check the DIP switch settings on the option unit.
2. Install the correct option units.
3. Replace the option unit.