1. Items to confirm before starting up CC-Link system

Confirm the following items before starting up the CC-Link system.
Is the CC-Link compatible module accurately connected?
1
(Refer to Chapter 2 section 2 or 3.)
Is the robot controller set to the CC-Link system specifications?
2
(Refer to Chapter 2 section 1.)
Are the CC-Link compatible module station No. and communication speed correctly set?
3
(Refer to Chapter 2 section 1.)
Is the ferrite core connected to the power input cable to the robot controller?(Refer to
4
Chapter 2 section 4.)
Is the CC-Link system cable accurately connected to the CC-Link compatible module?
5
(Refer to Chapter 2 section 5.)
Was the line test from the master station PLC correct?
6
(Refer to the master station PLC instruction manual.)
Is the master station PLC set for the 4-station occupying remote device?
7
(Refer to the master station PLC instruction manual.)
Is the master station PLC exchanging the data for four stations? (The data for four
8
stations must always be exchanged.)
Has the initial data process been carried out between the master station and robot
9
controller? (Refer the initialization process in Chapter 3 section 2.)
Is the master station PLC judging that the robot controller is correctly functioning using
10
RX(n+7)8 (remote Ready)? (Refer the samples in Chapter 5 section 4.)
n
NOTE
The dedicated input of STD.DIO connector provided on the RCX40/141/142
controllers will be disabled except for an interlock signal (DI 11). When the Board
condition (external 24V monitor control) of system parameters is set invalid, the
interlock signal (DI 11) will also be disabled. On the RCX221/222, the dedicated
input of STD.DIO connector will be disabled, but the interlock signal (DI 11) in
SAFETY connector enabled.