5. Referring to communication data
2. Direct connection from DI n ( ) to SO n ( )
Parallel port input can be directly connected to serial port output. The relation of the
parallel port and serial port that can be connected is as follows.
Input device such as sensor
DI port →SO port
DI2()
DI3()
Chapter
DI4()
3
DI5()
n
NOTE
When the port specifi ed by SIO is identical with the port used by the program, the
output results might be inaccurate.
[Operation]
1. Select a DI port (from items 5 to 8) in the "SYSTEM > OPTION > SIO" mode.
2. Press the
SYSTEM>OPTION>SIO V8.01
4.Direct SI5() −> DO5() NO
5.Direct SI5() <− DI2() NO
6.Direct SO3() <− DI3() NO
7.Direct SO4() <− DI4() NO
8.Direct SO5() <− DI5() NO
SET NO
3. Press the
the setting.
4. Press the
continue setting.
3-10
SO2()
SO3()
SO4()
SO5()
(EDIT) key.
F 1
(SET) key to enable the connection or the
F 1
key to quit setting or select another DI port with the cursor keys to
ESC
(NO) key to cancel
F 2