6. Parameter setting for CC-Link serial I/O board
6.1
Parameter setting for CC-Link serial I/O board
[Operation]
1. Press the
Chapter
2
2. Press the
parameter setting mode.
The option boards installed in the controller are displayed in order on the MPB
screen.
SYSTEM>PARAM>OP.BRD V8.18
1.DIO_N(1) VALID
2. . −−−
3.CCLnk(S1/10M) VALID
4. −−−
SELECT
Option boards installed into the option slots are displayed on the MPB screen.
Type
Option DIO
Serial I/O
Network
YC-Link
3. In "SYSTEM>PARAM>OP. BRD" mode, select the "CCLnk" with the cursor ( ↑ / ↓ ) keys
and press the
SYSTEM>PARAM>OP.BRD>SELECT V8.18
1.board condition VALID
2.remote cmd / IO cmd(SI05) VALID
3.Output MSG to SOW(1) INVALID
EDIT JUMP
2-10
(PARAM) key in "SYSTEM" mode to enter "SYSTEM>PARAM" mode.
F 1
(OP. BRD) key in "SYSTEM>PARAM" mode to enter the option board
F 5
Display
An option DIO board of NPN specifications is installed. The
DIO_N(n)
number in parentheses is an ID number.
An option DIO board of PNP specifications is installed. The
DIO_P(n)
number in parentheses is an ID number.
A CC-Link unit is installed. Letters in parentheses indicate a
CCLnk(n/m)
station number "n" and a communication speed "m".
A DeviceNet unit is installed. Letters in parentheses indicate a
D_Net(n/m)
MAC ID number "n" and communication speed "m".
A Profibus unit is installed. Letters in parentheses indicate a
Profi(n/m)
station address "n" and communication speed "m".
E_Net
An Ethernet unit is installed.
A YC-Link unit is installed. Letters in parentheses indicate a
YCLnk(Mn)
station number "n".
(SELECT) key.
F 1
Meaning