4. Noise measures
4. Noise measures
Two ferrite cores must be mounted on the input power cable when connecting to the CC-
Link system.
4.1
Mounting the ferrite core
Chapter
2
Mount two ferrite cores onto the input power cable connected to the input power
connector on the front panel of the robot controller.
w
WARNING
COMPLETELY SHUT OFF THE POWER SUPPLY TO THE INPUT POWER CABLE BEFORE
STARTING THIS WORK.
[Procedures]
1. Mount the two ferrite cores (supplied) onto the input power cable. The ferrite core
should be placed as close to the robot controller body as possible.
2. Fix the mounted ferrite core with an Insulock tie, etc.
c
CAUTION
Securely fi x the ferrite core. If the ferrite core is not mounted, trouble could
occur with the CC-Link system operations.
2-6