Inducement Strategy Of Scr System - Kohler KDI 3404TCR-SCR Owner's Manual

Hide thumbs Also See for KDI 3404TCR-SCR:
Table of Contents

Advertisement

2.9 Inducement strategy of SCR system

The inducement is the operation aimed at reducing the engine performance due to a malfunction or
tampering with the SCR system detected by the DCU.
The inducement degree is decided by the ECU according to the error detected by the DCU.
The inducement can have the following 2 levels:
Level 1: 25% reduction of the MAX available torque.
Level 2: 50% reduction of the MAX available torque and 40% reduction of MAX rpm available.
Before activating the inducement (level 1 or level 2) the ECU activates a warning or a warning light on the
car panel (refer to the car documentation for the warning type).
The information on the car panel or the activation of the inducement can occur for the following reasons:
®
Low AdBlue
level
®
Poor AdBlue
quality
Interruption of AdBlue
EGR valve malfunctioning
Tampering with the monitoring systems of the SCR system.
The inducement strategy is applied according to:
detected problem
hours passed.
NOTE: Hours are reset after 40h if the DCU does not detect any fault, otherwise the hours are
added to those already counted. For low AdBlue
liquid inside the AdBlue
The strategy for the different faults is listed below:
®
Low AdBlue
level
information activation on car panel: <10% of MAX level
Level 1 inducement: <2.5% of MAX level
Level 2 inducement: 0% of MAX level
®
Poor AdBlue
quality
information activation on car panel: upon fault detection
Level 1 inducement: after 10h from fault detection
Level 2 inducement: after 20h from fault detection
Interruption of AdBlue
information activation on car panel: upon fault detection
Level 1 inducement: after 10h from fault detection
Level 2 inducement: after 20h from fault detection
EGR valve malfunctioning
information activation on car panel: upon fault detection
Level 1 inducement: after 36h from fault detection
Level 2 inducement: after 100h from fault detection
Tampering with the monitoring systems of the SCR system
information activation on car panel: upon fault detection
Level 1 inducement: after 36h from fault detection
Level 2 inducement: after 100h from fault detection
TECHNICAL INFORMATION
®
supply
®
tank, and the fault hours are not counted.
®
supply
®
level, activation depends on the percentage of
2
25