5
Operations for the SCR system
5.4
POINT
PERIOD
1
up to 2 months
Start-up after 2
1a
months
2
up to 9 months
Start-up after 9
2a
months
3
over 9 months
Start-up after
3a
9+ months
EN
46
INFORMATION ABOUT MAINTENANCE
OPERATION
Perform the operations described in point 1 of Tab. 5.3
Fill the AdBlue® tank with AdBlue® to the MAX level
The ambient temperature must be kept between -40 and 40 °C
Do not disconnect any electrical or hydraulic connections
Before starting the engine, check Para. 5.2 for maintenance
operations.
Consult the machine's manual to connect the battery and start the
engine.
Perform the operations described in point 2 in Tab. 5.3
Fill the AdBlue® tank with AdBlue® to the MAX level
The ambient temperature must be kept between -40 and 25 °C
Do not disconnect any electrical or hydraulic connections
Before starting the engine, check Para. 5.2 for maintenance
operations.
Consult the machine's manual to connect the battery and start the
engine.
Perform the operations described in point 3 of Tab. 5.3
Fill the AdBlue® tank with AdBlue® to the MAX level
The ambient temperature must be kept between -40 and 25 °C
Do not disconnect any electrical or hydraulic connections
Before starting the vehicle, proceed as follows:
Replace the AdBlue® in the tank (consult the machine's manual)
Replace the AdBlue® filter (Par. 6.5)
Check Par. 5.2 for maintenance frequency.
Consult the machine's manual to connect the battery.
Start the engine. If faults are detected when starting the engine or
during operation, turn off the engine and wait 5 mins before starting
the engine.
If the fault persists, contact KOHLER authorised workshops.