Riello Array AR 399 SE Installation, Operation And Service Manual page 75

Table of Contents

Advertisement

APPENDIX
Nr. dis-
Par.
Menu
played
No.
Display
Dair
M1
139
active
Mini-
M1
140
mum
Flow
Anti-Le-
M1
107
gionella
day
Anti-Le-
M1
108
gionella
Hour
Permit
Emer-
M2
72
gency
Mode
Emer-
gency
M2
74
Set-
point
Delay
Per Start
M2
75
Next
Mod.
Delay
Per Stop
M2
76
Next
Mod.
Delay
Quick
M2
142
Start
Next
Delay
Quick
M2
143
Stop
Next
Hyst.
Down
M2
77
Start
Module
Hyst.
M2
78
Up Stop
Module
Hyst.
Down
M2
144
Quick
Start
Description
Activates bleeding the system's air. To activate air
bleeding, it is necessary to switch on the boiler
and change the parameter from "No" to "Yes".
Wait for one minute. Switch off and restart. At this
stage, when it is restarted the boiler will initiate
the automatic bleeding procedure (lasting around
20 minutes). With the parameter set to "Yes", the
procedure is carried out each time the boiler is
switched off and restarted using its master switch.
The value must be set to "No" if you do not wish to
initiate the bleeding procedure when the boiler is
switched on.
Defines the flow rate below which the boiler is
switched off. The value varies depending on the
model.
Sets the weekday on which the anti-Legionella
procedure is carried out.
Sets the time of the day during which the anti-Le-
gionella procedure is carried out.
Activates the emergency mode. This mode comes
on when communication between Managing and
the primary circuit's sensor is lost. In this event, if
Par. 72 is set to "Yes", the cascade is initiated, work-
ing to the fixed set-point determined by Par. 74.
Set-point active in emergency mode.
Defines the stand-by time in seconds to restart the
subsequent cascade boiler in normal start mode.
Defines the stand-by time in seconds to switch off
the last cascade boiler on in normal Off mode.
Defines the stand-by time in seconds to restart the
next cascade boiler in quick start mode.
Defines the stand-by time in seconds to switch off
the last cascade boiler on in Quick Stop mode.
Defines how many degrees the temperature mea-
sured by the primary circuit's sensor must fall below
the set-point in order for the subsequent boiler to
be started after the time interval set by Par. 75.
Defines by how many degrees the temperature
measured by the primary circuit's sensor must go
above the set-point in order for the subsequent
module to be switched off after the time interval
set by Par. 76.
Defines how many degrees the temperature mea-
sured by the primary circuit's sensor must go below
the set-point in order for the subsequent boiler
to be started after the time interval set by Par. 142
(quick-start mode).
Range
Yes, No
0 - 26
(0.0 - 100)
Sun - Sat
0 - 23
Yes/No
68 - 194
(20 - 90)
5 - 255
5 - 255
5 - 255
5 - 255
0 - 72
(0 - 40)
0 - 72
(0 - 40)
0 - 72
(0 - 40)
75
75
RECYCLING AND DISPOSAL
Default
Access
UM
setting
type
No
I
gal/
Depends
min
on boiler
I
(l/
model
min)
Sun
Day
I
0
Hour
I
Yes
U
158 (70)
°F (°C)
I
120
Sec.
I
30
Sec.
I
60
Sec.
I
15
Sec.
I
9 (5)
°F (°C)
I
7 (4)
°F (°C)
I
36 (20)
°F (°C)
I
APPENDIX
Category
General
General
DHW
DHW
Cascade
Cascade
Cascade
Cascade
Cascade
Cascade
Cascade
Cascade
Cascade

Advertisement

Table of Contents
loading

This manual is also suitable for:

Array ar 500 se2018172120181722

Table of Contents