Riello Array AR 399 SE Installation, Operation And Service Manual page 54

Table of Contents

Advertisement

APPENDIX
RECYCLING AND DISPOSAL
APPENDIX
Error no.
Error
141
T_SELECTION3_OPEN
142
T_OPTIONAL1_OPEN
143
T_OPTIONAL2_OPEN
144
T_AMBIENT_OPEN
145
T_CHIMNEY_CLOSED
146
T_EXCHANGE1_CLOSED
147
T_EXCHANGE2_CLOSED
148
T_SELECTION1_CLOSED
149
T_SELECTION2_CLOSED
150
T_SELECTION3_CLOSED
151
T_OPTIONAL1_CLOSED
152
T_OPTIONAL2_CLOSED
153
T_AMBIENT_CLOSED
154
WD_CONFIG_ERROR
155
FLUE_PRESSURE_ERROR
156
AIR_DAMPER_ERROR
157
T_SECONDARY_SUPPLY_OPEN
158
T_SECONDARY_RETURN_OPEN
159
T_SECONDARY_SUPPLY_CLOSED
160
T_SECONDARY_RETURN_CLOSED
161
FILL_WARNING
162
FLUE_BLOCKED
163
LOWEXFLOW_PROTECTION
WARNINGS
Error no.
Error
200
CC_LOSS_COMMUNICATION
201
CC_LOSS_BOILER_COMM
202
OUTDOOR_WRONG
203
T_SYSTEM_WRONG
204
T_CASCADE_WRONG
205
HIGH_LIMIT_TEST_WAIT_ACTIVE
206
CH_SETPOINT_TOO_HIGH
207
DHW_SENSOR_WRONG
208
ZONE_SENSOR_WRONG
209
BOILER_DEMAND-DISABLED
Description
Selection 3 sensor open
Optional 1 sensor open
Optional 2 sensor open
Ambient sensor open
Chimney sensor shorted
Exchange 1 sensor shorted
Exchange 2 sensor shorted
Selection 1 sensor shorted
Selection 2 sensor shorted
Selection 3 sensor shorted
Optional 1 sensor shorted
Optional 2 sensor shorted
Ambient sensor shorted
Watchdog fan configuration setting error
Flue pressure switch is open
Air Damper feedback is not received when
the relevant output is closed
Secondary circuit supply sensor open
Secondary circuit return sensor open
Secondary circuit supply sensor shorted
Secondary circuit return sensor shorted
Pressure is too low, demand has stopped
but no error needed to be stored at this
time
Flue is blocked, demand needs to be
stopped with fan at ignition speed
but no error needed to be stored at this
time
Flow is too low, demand needs to be
stopped with fan at ignition speed but no
error needed to be stored at this time
Description
Cascade System: Leading burner lost
communication with one of the de-
pending burners
Cascade System: Leading boiler lost
communication with one of the de-
pending boilers
Outdoor sensor is open or shorted
T_System sensor is open or shorted
T_Cascade sensor is open or shorted
Too many physical high limit test
attempts within 24 hours.
Current setpoint is higher than 176°F
(80°C)
DHW sensor is open or shorted
Zone sensor is open or shorted
All incoming demand is disabled
54
54
Checks
Solutions
a- Remove any obstructions from the
a- Check for any obstruction
exhaust system;
in the exhaust system;
b- Remove any obstruction from con-
b- Check the condensate
densate discharge and confirm if the
discharge.
condensate can flow freely.
Checks
Solutions