HEAT EXCHANGER

INSPECTION

1.Measure:
S Filler cap opening pressure
Cap opens at pressure below the specified
pressure ! Replace.
Cap opening at pressure:
80 X 100 kPa
(0.8 X 1.0 kg/cm
11.44 X 14.30 psi)
Measurement steps:
S Attach the cooling system tester 1 (90890
-01325, YU-24460-01) to the coolant filler cap
2 .
S Apply the specified pressure for 10 seconds,
and make sure there is no pressure drop.
–56–