8301-073 Dust (Particulate) Sensor

The following measurements are taken across V+ and GND on Dust Sensor Alarm B
Dust
ppm
0
3
6
9
12
15
18
21
24
27
30
33
36
39
42
45
48
51
54
57
60
63
66
69
72
75
78
81
84
87
90
93
96
99
102
Manual 2100-694B
Page
50 of 62
8301-073 Sensor: Dust/Volts
Signal
Dust
VDC
ppm
0.00
105
0.05
108
0.10
111
0.15
114
0.19
117
0.24
120
0.29
126
0.34
126
0.39
129
0.44
132
0.49
135
0.53
138
0.58
141
0.63
144
0.68
147
0.73
150
0.78
153
0.83
156
0.87
159
0.92
162
0.97
165
1.02
168
1.07
171
1.12
174
1.17
177
1.21
180
1.26
183
1.31
186
1.36
189
1.41
192
1.46
195
1.50
198
1.55
201
1.60
204
1.65
207
TABLE 17
Signal
VDC
1.70
1.75
1.80
1.84
1.89
1.94
1.99
2.04
2.09
2.14
2.18
2.23
2.28
2.33
2.38
2.43
2.48
2.52
2.57
2.62
2.67
2.72
2.77
2.82
2.86
2.91
2.96
3.01
3.06
3.11
3.16
3.20
3.25
3.30
3.35
Dust
Signal
ppm
VDC
210
3.40
213
3.45
216
3.50
219
3.54
222
3.59
225
3.64
228
3.69
231
3.74
234
3.79
237
3.83
240
3.88
243
3.93
246
3.98
249
4.03
252
4.08
255
4.13
258
4.17
261
4.22
264
4.27
267
4.32
270
4.37
273
4.42
276
4.47
279
4.51
282
4.56
285
4.61
288
4.66
291
4.71
294
4.76
297
4.81
300
4.85
303
4.90
306
4.95
309
5.00