Thermostat Connection (optional)
Use only a thermostat rated for 500 millivolts.
Check the table below for the appropriate gauge thermostat
wire to use for the length of lead required in your installation.
Thermostat
Wire / Gauge
18
16
14
1. Install the wall thermostat in the desired location and run
the wires to the stove location. Terminate these leads
with 1/4" female connectors.
2. Connect the thermostat wires to the valve. (Figure 42)
Install the Stove Front
Insert the handle stub into the hole in the front casting.
Fasten in place with the 3/8" locking nut provided. (Figure
43)
The front attaches to the stove by four steel tabs that
engage with corresponding cast ribs onto the sides and
bottom of the stove body. Position the front about 3" down
from stove top and lift the plate to engage the upper tabs
behind the adjacent ribs on the sides. (Figure 44) Then
lower the front into position, so the lower tabs engage with
the corresponding ribs at the bottom.
When properly installed, the bottom of the stove front cannot
be pulled away from the sides without also lifting it.
3-90-693831
Hearth and Home Technolgies • Oxford Direct Vent Installation Manual_R6 • 08/17
Maximum Run
20 Feet
20-40 Feet
up to 60 Feet
3/8" Locking Nut
Figure 43 - Insert handle stub into hole in front. Secure with 3/8"
locking nut.
Engage steel tabs behind
the cast iron bosses
Figure 44 - Install the - front plate.
Handle Stub
ST773
handle assy
6/6/03
Bottom tabs engage
notch in the leg
ST1126
install stove front
22