Install The Log Set; Connect Gas Supply Line - Hearth and Home Technologies OXDV30SP Installation And Operating Instructions Manual

Direct vent
Table of Contents

Advertisement

Attach the first section of venting to the draft hood.
Depending on the length of the individual venting sections
and the lengths of the decorative pipe (if installed), you may
need to slip the decorative pipe over the venting sections
before attaching upper sections to lower ones. The sections
of decorative pipe should be oriented with their seams (if
any) toward the wall; sections usually do not need to be
fastened at each joint, other than slip sections. If the layout
includes a slip section, this should be the last section of
pipe visible in the room, at the ceiling. Complete the venting
according to the vent maker's instructions.
Figure 33 - Install draft hood adapter.

Install the Log Set

1. Remove the logs from their packaging, and inspect
each piece for damage. DO NOT INSTALL DAMAGED
ST767
LOGS.
DW
2. Install the rear log by centering it to the rear of the firebox
attach draft hood
on the sheet metal shelf, Figure 34. The log should touch
5/15/03 djt
the back wall of the firebox when installed properly.
3. Place the right log by matching the hole on the underside
of the right log with the pin located on top of the rear log,
Figure 34. Set the front of the log on the burner and push
toward the right side of the firebox, the front right corner
of the log will touch the side wall of the firebox.
4. Place the left log by matching the hole on the underside
of the left log with the pin located on top of the rear log,
Figure 34. Set the front of the log on the burner and push
toward the left side of the firebox, the front left corner of
the log will touch the side wall of the firebox.
5. Lay the lava rocks in the open area of the burner in front
of and between the decorative grate and the right and left
logs. Use the lava rock to cover brackets on the burner,
Figure 34.
19
Hearth and Home Technolgies • Oxford Direct Vent Installation Manual_R6 • 08/17
Left Log
Rear Log
Figure 34 - Install the back, left and right logs.
Connect the Gas Supply Line
Check the Rating Plate attached by a steel cable to the
firebox, to confirm that you have the appropriate firebox for
the type of fuel to be used. The Oxford may be converted
from one gas to another using the appropriate Fuel
Conversion Kit.
LG141
Stardance
!
Install logs 1
12/11/00 djt
This appliance should only be connected by a
qualified gas technician. Test to confirm manifold
pressures as specified below.
The heater and its individual shutoff valve must be
disconnected from the gas supply piping during any
pressure testing of that system at test pressures in
excess of 1/2 psig (3.5 kPa).
The heater must be isolated from the gas supply
piping system by closing its individual manual
shutoff valve during any pressure testing of the gas
supply piping system at test pressure equal to or
less than 1/2 psig.
There must be a gas shutoff between the stove and
the supply.
In order to connect Natural Gas, use a fitting with
3/8" NPT nipple on the valve side and 1/2" natural
gas supply line with an input of 28,000 BTUs at a
manifold pressure of 3.5" and minimum inlet supply
for adjustment of 5.5" w.c.
In order to connect Propane, use a fitting with 3/8"
NPT nipple on the valve side and 1/2" propane
gas supply line with an input of 28,000 BTUs at a
manifold pressure of 10.0" and minimum inlet supply
for adjustment of 11.0" w.c.
Right Log
Lava Rock
Placement
Decorative Grate
CAUTION
3-90-693831