Install the Optional Fan

If you are installing the optional convection Fan Kit #2767
(FK26), continue here. If you are not installing a Fan Kit, go
to "Venting System Assembly".
1. The fan kit includes a Blower Assembly and a Rheostat
Assembly, connected by a cable. (Figure 12) The Blower
Assembly mounts to the bottom rear of the stove, and the
Rheostat mounts to the valve cover plate. The assembly
includes a 'snapstat' which automatically turns the fan
On (or Off) above (or below) approximately 109°. The
Rheostat also provides a range of fan speed settings
from Off (which overrides the snapstat function) to High.
Unpack and inspect the Blower assembly. Confirm that
the fan spins freely.
!
This appliance is equipped with a three-prong (grounded)
plug for your protection against shock hazard and should
be plugged directly into a properly grounded three-prong
receptacle. Do not cut or remove the grounding prong
from this plug.
Not Used on
RF Models
Not
Used on
Oxford
Blower
Assembly
Figure 12 - Fan kit components.
2. Remove the rear skirt insert panel at the bottom of the
ST473
Rear Skirt (Figure 13) and fasten the blower assembly
Fan parts
to the firebox back with the two Phillips pan-head bolts
#2767 FK26
9/29/00
originally installed in the firebox back. ('1', Figure 14)
3. Attach the snapstat assembly to the snapstat bracket
with two sheet-metal screws. ('2', Figure 14) Attach
the snapstat bracket to the stove with a hex-head bolt
passing through the bracket and into the stove base. ('3',
Figure 14)
4. The rheostat control switch attaches to the left side of the
valve bracket at the front of the stove.
13
Hearth and Home Technolgies • Oxford Direct Vent Installation Manual_R6 • 08/17
WARNING
Snapstat
Bracket
Snapstat/
Extension
Assembly
Rheostat
Assembly
Not Used
on RF
Models
Connect to PC Board
on RF Models Only
Remove retaining nut from shaft of rheostat. (if
preinstalled)
Insert the rheostat through the hole in the back of the left
side of the valve bracket, aligning the locator pin with the
smaller hole in that bracket.
Thread the retaining nut onto the shaft of the rheostat,
tightening with a wrench. Do not overtighten.
Attach the control knob to the rheostat shaft.
Use the wire tie to secure the fan and rheostat wire
harnesses together.
Rear Skirt
Sheet Met-
al Screws
Rear Skirt Insert
Figure 13 - Remove rear skirt insert.
Star Washer
Sheet Metal Screws
2
Phillips
1
Pan
Head
Bolts
Star
Washer
Figure 14 - Attach the fan assembly and the snapstat.
ST314
Fk26ce
attach fan
1/24/00
Rheostat
Retaining Collar
Rheostat Knob
Figure 15 - Attach the fan rheostat.
ST1123
rear skirt insert
Snapstat
1/4" - 20
Hex Bolt
Snapstat