Unpack Stove; Installation Requirements; Locating The Stove; Clearance Requirements - Hearth and Home Technologies OXDV30SP Installation And Operating Instructions Manual

Direct vent
Table of Contents

Advertisement

Installation:
Unpack the Stove
Using a 1/2" wrench, remove (4) lag bolts installed through
the shipping brackets and into the skid. With help, slide the
stove forward and tilt over so the back of the stove is resting
on the skid. Remove (2) 1/4-20 x 5/8" bolts and washers
holding the legs and shipping brackets to the unit and set
aside. Remove the shipping bracket and re-install the 1/4-20
bolts and washers through the legs into the cast side. Repeat
previous steps to the opposite side. Once complete, stand
the unit upright.
Installation Requirements
The installation must conform with local codes or, in the
absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1/NFPA 54 - latest edition. (EXCEPTION: Do
not derate this appliance for altitude. Maintain the manifold
pressure at 3.5" w.c. for Natural Gas, and 10" w.c. for
Propane).
In Canada, installation must be in accordance with the
current CSA B-149.1 Installation Codes and/or local codes.
The installation should be done by a qualified service
person who is familiar with the building codes and
installation techniques appropriate for your area to
accomplish a safe and effective installation.
Your dealer or your local gas supplier will be able to
refer a qualified service person.
!
Due to high temperatures, the HEATER should be
located out of traffic and away from furniture and
draperies.
The surface of the Heater Is hot when it is in use. Young
children should be watched carefully when they are
in the same room when the Heater is in use, and they
should be taught to avoid the hot surface. Keep any
objects that can burn well away from the Heater, and
observe the recommended clearances that follow.

Locating the Stove:

In choosing a location for the stove, consider:
• The location of outside walls;
• Where additional heat is needed:
• Where family members gather most often;
• The vent system requirements.
NOTE: We do not recommend the use of wallpaper next
to this stove. Over time, radiant heat may cause the
wallpaper to shrink, or may adversely affect the binders in
the wallpaper adhesive.
6
Hearth and Home Technolgies • Oxford Direct Vent Installation Manual_R6 • 08/17
WARNING
Direct Vent System Only
A
E
A. Flat on corner wall
B. Room Divider
C. Island
ST207b
Dutchwest
Stove locations
Figure 2 - Possible stove locations.
5/15/03 djt
Clearance Requirements:
Minimum Clearances to Combustible Materials
Measure side clearances as shown in Figures 5 and 6 from
the outer edge of the cast iron stove top. Measure rear
clearances from the outermost surface of the steel rear skirt.
The heater is approved for installation into an alcove
constructed of combustible materials to the dimensions and
clearances shown on the next page.
The same clearances apply in a standard parallel installation.
!
Always maintain required clearances (air spaces) to
nearby combustibles to prevent fire hazard. Do not
fill air spaces with insulation. All venting components
must maintain a 1" (25 mm) clearance to combustible
materials. Maintain a 6" (150 mm) clearance when using
a single wall pipe.
• The gas appliance and vent system must be vented
directly to the outside of the building and never be
attached to a chimney serving a separate solid fuel
or gas-burning appliance. Each direct vent appliance
must use its own separate vent system. Common
vents are prohibited.
• Refer to the manufacturer's instructions included
with the venting system for complete installation
procedures.
D
B
C
D. Cross Corner
E. Flat on wall
WARNING
3-90-693831

Advertisement

Table of Contents