Parallel Installation:

Minimum Clearance and Flue Centerline
Direct Vent and Natural Vent
C
D
C L
B
Stove Clearances
A
B
Pipe Centerlines
C
ST128b
D
Stardance
Figure 3 - Parallel installation, minimum back and side clearances
flue centerline
and flue centerlines.
9/28/00 djt

Corner Installation:

Minimum Clearance and Flue Centerline
Direct Vent and Natural Vent
B
B
A
Stove Clearances
A
Pipe Centerlines
B
Figure 4 - Corner installation, minimum corner clearances and
flue centerline.
3-90-693831
Hearth and Home Technolgies • Oxford Direct Vent Installation Manual_R6 • 08/17
C L
A
4" (102 mm)
4" (102 mm)
15-1/2" (395 mm)
9" (229 mm)
A
4" (102 mm)
14-1/2" (370 mm)
ST129c
Dutchwest
corner specs
5/15/03 djt
Wall Centerline from Floor
A
Effective Minimum (A)
Wall Thimble 57-1/2" (1461 mm) (HHT Pipe)
Centerline
53-1/2" (1359 mm) (Simpson DuraVent Pipe)
Figure 5 - Minimum wall thimble centerline.

Wall and Ceiling Clearances

B
C
A Rear Wall
B Minimum Clearance
ST1122
C Minimum Alcove Height
Min. clearance
D Maximum Alcove Height
Sidewall Clearance
Figure 6 - Dimensions and clearances to ceiling or alcove.
Hearth Requirements
The heater must be installed on rigid flooring. When the
heater is installed directly on any combustible surface other
than wood flooring, a metal or wood panel extending the
full width and depth of the unit must be used as the hearth.
There are no other hearth requirements.
ST1121
wall thimble
D
A
4" (102 mm)
45-1/2" (1156 mm)
73-1/2" (1867 mm)
48" (1220 mm)
4" (120 mm)
7