9.3 SUSPEND THE FIRST ST ACK
STEPS:
•
Check that all red Locking Levers are in the locked position, then engage the hoist to lift the array off the ground. As the hoist
1
lifts, each cabinet will expand to the correct angle. As each cabinet reaches the correct inter-enclosure angle , it stops ex-
panding.
•
When all cabinet angles are set, and the array is suspended a short distance off the ground, disconnect the Vertical Transporter
2
by removing the two rear quick release pins, followed by the front pins.
VTX A8 | Rigging Manual
41
1
2