6.3 ANGLE SELECTION

Every VTX A8 has an Angle Selection panel on either side of the cabinet. These panels are used to select the cabinet-to-cabinet splay
angle. The panels offer eleven unique positions, labeled in degrees. The positions range from 0.25 to 10 degrees.
VTX A8 ANGLE OPTIONS: 0.25°, 0.5°, 1°, 1.5°, 2°, 2.5°, 3°, 4°, 6°, 8°, 10°
A dedicated quick release pin is available for setting the angle. Angles are selected while VTX A8 cabinets sit on a VTX A8 VT cart rest-
ing on the ground. Since the quick release pins are not under load when the system is on the ground, they can be moved freely to the
desired position. During transportation, VTX A8 cabinets should always be set to 10 degrees. This ensures the rigging system is locked,
preventing any accidental movement or unintended change of angle.
To select an angle, remove the quick release pins from the storage position (10°) and set them to the position for the desired angle. Lifting
the array from the ground shifts weight to the quick release pins, making angle selection no longer possible.
CAUTION: Every quick release pin in a VTX A8 system must be set in a hole before the array is flown . Do not sus-
pend a VTX A8 system if any pins hang free .