OPERATION
Automatic reheating function
● A given heating zone must be set to a
power level (0).
● Pressing sensor (-) (3) results in switching
to a power level (9).
● Then touch sensor (+) (2) of a given he-
ating zone. Letter „
indicator.
● Now, using sensor (-) (3), select the target
power level.
On the indicator of power level of a given
heating zone, letter „
nately with the power level programmed
by the user.
After the time when additional power is
supplied, the heating zone will automati-
cally switch onto the preselected power
level that remains visible on the indicator.
If after switching on the fast automa-
tic reheating system, the power level
sensor is set to „9" for longer than 3
seconds, namely the choice of power
level is not made, the function of fast
automatic reheating will switch off.
If a pot is removed from the heating
zone and put back again before the
end of automatic reheating cyckle,
full power reheating will continue
until the end of the cycle.