6.6 Exterior maintenance
Painted products may change colour after several years usage.
The surface should be cleaned and brushed free of any loose
particles before new paint is applied.
Enamelled products must only be cleaned with a clean, dry
cloth. Do not use water and soap. Any stains can be removed
with a cleaning fluids (Oven cleaner etc.).
7.0 Service
Warning! Any unauthorised change to the product is illegal.
Only use original spare parts!
7.1 Changing the burn plates/inner
bottom plate (fig. 3)
Remove the log retainer (3A)
Remove the baffle plate (the vermiculite plate) (3B)
Remove the side burn plates (3C) by lifting them up a little
and then out. (Be aware if using tools, that vermiculite plates
may be damaged by rough handling).
Unscrew the screws at the back of the rear burn plate (3D)
and remove the burn plate. Make sure the gasket is intact
and properly positioned.
Remove the ash cover and then lift up and remove the
inner bottom plate.
Follow the same procedure for installation, but in the
opposite sequence.
7.2 Changing the baffle plate (fig. 7)
Lift the baffle plate (the vermiculite plate) (7A) forward and
remove it through the door. Access is then easy to baffle
plate II (7B) if this needs to be removed. It rests on two ribs
in the side plates. Edge it down and remove it through the
door.
For re-installation follow the same procedure in the opposite
sequence.
Reasons for operational
8.0
problems - troubleshooting
Poor draught in the stove following
installation
Check the length of the chimney and that it complies with
national laws and regulations. Make sure that the minimum
cross section on the chimney is large enough. See also «2.0
Technical data» and «4.5 Chimney and flue pipe» for
information.
Make sure that there is not anything preventing the smoke
gasses from escaping: Branches, trees, etc.
The stove has poor draught and the fire
extinguishes after a while
Make sure that the firewood is sufficiently dry
Make sure that there is no negative pressure in the house,
close mechanical fans and open a window close to the stove.
Check that the air vent is open.
Check that the flue outlet is not clogged by soot
If an unusual amount of soot accumulates on
the glass
Some soot will always stick to the glass, but the quantity
depends on:
Humidity of the fuel.
Local draught conditions.
Regulating the air vent.
Most of the soot will normally burn off when the air vent is
opened all the way and a fire is burning briskly in the
fireplace.«6.1 Cleaning the glass - good advice» .