System messages

After the error has been eliminated, all error messages must be acknowledged by pressing START on the interior control panel
No.
Status message
Excess
01
bimetal
02
Maximum tanning time!
Excess
03
exhaust fan!
KBL7 Hardware error In-
12
put-Controller
Maximum
13
flash memory reached
Error! SD card read error
14
(CRC fault)
Error! no access to the
15
SD card
Parameter storage not
17
found, please connect
and restart
Parameter
18
valid serial number
CAN-BUS: Interior dis-
19
play V1 is incompatible
CAN-BUS: preSelection
20
display V1 is incompat-
ible
CAN-BUS: audio module
21
full V1 is incompatible
CAN-BUS: RGB module
22
V1 ist incompatible
Parameter storage write
23
error
Parameter storage read
24
error
Frequency detection: de-
25
tection failed!
Frequency
26
power supply connection
faulty (connector X6/E6)!
44
O p e r a t i n g I n s t r u c t i o n s | megaSun space 2000
Description
temperature
Bimetal switch triggers.
Enabling signal from coin-box system
comes in longer than the time value
approved under "Maximum tanning
time" (voltage remains connected)
temperature
Bimetal switch in the fan triggers.
Mainboard defective.
write
cycle
Maximum write cycle flash memory
reached.
Update via SD card failed (CRC fault).
Update via SD card failed (access er-
ror).
Parameter storage not found, please
connect and restart.
storage
no
Parameter storage no valid serial
number.
CAN-BUS operators incompatible.
Parameter storage write error.
Parameter storage read error.
Frequency detection failed.
detection:
Frequency detection failed. No mains
voltage.
ERROR MESSAGES
Remedy
Check the air-intake/air-discharge system. Let
the tanning device cool down.
Disconnect from the coin-box system.
Make sure the fan runs freely. Check the air-
intake/air-discharge system. Let the tanning
device cool down.
Contact your Customer Service.
Contact your Customer Service.
SD card check / replace.
SD card check / replace
Check connector parameter storage. If neces-
sary replace parameter storage.
Contact your Customer Service.
Use CAN-BUS operaters V2.
Check connector parameter storage. If neces-
sary replace parameter storage.
Check connector parameter storage. If neces-
sary replace parameter storage.
Restart the controller. Contact your Customer
Service after the third unsuccessful restart.
Check mainboard connector X6/E6.
.