Mobile Home Installation - Model; Gas Installation; Optional Wall Switch - Napoleon Knightsbridge GDS60-1N Installation And Operation Manual

Table of Contents

Advertisement

Available languages

Available languages

4.4
mobile home installation - model GDS60-1
In Canada, mobile home installation may be vented horizontally or vertically. In the United States, it may only be
installed vertically. See "vertical venting" or "horizontal air terminal installation" section for installation.
For mobile home installations, the appliance must be fastened in place. It is recommended that the appliance be
secured in all installations. Use the levelling / securing kit, GDSLL-KT for this purpose.
4.5

gas installation

WARNING
!
Risk of fi re, explosion, or asphyxiation. Ensure there are no ignition sources such as sparks or open fl ames.
Support gas control when attaching gas supply pipe to prevent damaging gas line.
Always light the pilot whether for the fi rst time or if the gas supply has run out with the glass door opened
or removed. Purging of the gas supply line should be performed by a qualifi ed service technician. Ensure
that a continuous gas fl ow is at the burner before closing the door. Ensure adequate ventilation. For gas and
electrical locations, see "dimensions" section.
All gas connections must be contained within the appliance when complete (gas fi replaces only).
High pressure will damage valve. Disconnect gas supply piping before testing gas line at test pressures above
1/2 PSIG.
Valve settings have been factory set, do not change.
Installation and servicing to be done by a qualifi ed installer.
Move the appliance into position and secure.
If equipped with a fl ex connector, the appliance is designed to accept a 1/2" (13mm) gas supply. Without the
connector, it is designed to accept a 3/8" (9.5mm) gas supply. The appliance is equipped with a manual shut
off valve to turn off the gas supply to the appliance.
Connect the gas supply in accordance to local codes. In the absence of local codes, install to the current
CAN/CSA-B149.1 Installation Code in Canada or to the current National Fuel Gas Code, ANSI Z223.1 / NFPA
54 in the United States.
When fl exing any gas line, support the gas valve so that the lines are not bent or kinked.
The gas line fl ex-connector should be installed to provide suffi cient movement for shifting the burner assembly
on its side to aid with servicing components.
Check for gas leaks by brushing on a soap and water solution. Do not use open fl ame.
4.6

optional wall switch

For ease of accessibility, an optional remote wall switch may be installed in a convenient location. Route 2 strand
solid core millivolt wire from the gas appliance to the wall switch. The recommended maximum lead length
depends on the wire size:
WIRE SIZE
14 gauge
16 gauge
18 gauge
DIRECT VENT MODEL GDS60-1: Disconnect one of the wire leads to the on/off switch then connect the wire
leads from the optional wall switch / remote. See "wiring diagram" section.
B-VENT MODEL GS60-1: Disconnect one of the wire leads to the on/off switch then connect the wire leads from
the optional wall switch / remote / spill switch to "B" vent adaptor. See "WIRING DIAGRAM" section.
MAX. LENGTH
100 feet (30m)
60 feet (18m)
40 feet (12m)
installation
EN
31
W415-1328 / C / 12.06.18