4.7.2 installing natural vent

Follow the instructions of the "B" vent manufacturer for chimney
installation.
A.
Remove the access plate. Remove and discard the air
intake cover plate located directly behind the access
plate.
B.
Feed the 2 wires, supplied, through the 7" (178mm)
collar at the top of the unit, bring them out the air intake
opening but behind the rear panel as shown.
NOTE: Ensure that 2 female ends remain at the
top. Re-secure the access plate.
C.
Remove the spill switch bracket from the rear of the
adapter. Unscrew the spill switch and discard the
bracket. Attach the spill switch to the bracket supplied
with the appliance and secure onto the adapter.
D.
Bring the wires through the lower hole in the adapter. To
pass the wires through the hole more easily, temporarily tape
the two terminals together.
E.
With the spill switch opening aligned to the back of the
appliance, take hold of the adapter base and push the crimped
edge into the appliance fl ue collar.
F.
Connect the upper wire terminals to the spill switch.
G.
Disconnect the wire leads to on/off switch, see "wiring
diagram" section and reconnect to the ends of the spill switch
wires. Leave all excess wire in an orderly manner.
For aesthetics, the adapter has been designed to accept a standard
matte black 7" (178mm) appliance pipe and the Napoleon® decorative
brass band (standard with the GS-150KT). Both are available from your
local authorized dealer / distributor.

4.7.3 natural vent

Attach the natural vent label, shown, in the control area of the appliance.

4.7.4 combustion air

This appliance needs air for safe operation and must be installed in such a way that adequate combustion air is
available.
ATTACH THIS LABEL IN THE CONTROL AREA OF THE APPLIANCE.
THIS APPLIANCE HAS BEEN CONVERTED TO A NATURAL VENT
ATTACHEZ CET ÉTIQUETTE DANS LA RÉGION DE CONTRÔLE DU FOYER.
CET APPAREIL A ÉTÉ CONVERTI À UN MODÈLE À TIRAGE
NATUREL.
ACCESS PLATE
LOCATION
AIR INTAKE COVER
PLATE LOCATION
SPILL
SWITCH
MODEL.
installation
ADAPTER
W385-0160 / B
W415-1328 / C / 12.06.18
EN
33