Rating Plate Information; Mobile Home Installation - Napoleon Bayfield GDS25N-1 Installation And Operation Manual

Natural / propane gas
Table of Contents

Advertisement

Available languages

Available languages

general information
EN
1.3

rating plate information

A
CONFORMS TO / CONFORME AUX: ANSI Z21.50-2016, CERTIFIED TO / CERTIFIE CSA 2.22-2016 VENTED DECORATIVE GAS APPLIANCE / FOYER À GAZ VENTILÉ.
APPROVED FOR BEDROOM, BATHROOM & BEDSITTING ROOM INSTALLATION. SUITABLE
FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT
STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA
OR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND
SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT
APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFAC-
TURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A. FOR
USE WITH BARRIER W010-3295. FOLLOW THE INSTALLATION INSTRUCTIONS
LOCATED IN THE INSTALLATION MANUAL
MANIFOLD PRESSURE: 3.5" W.C. (NG)
PRESSION AU COLLECTEUR: 3.5" D'UNE
COLONNE D'EAU(GN)
MIN SUPPLY PRESSURE: 4.5" W.C.(NG)
PRESSION D'ALIMENTATION MIN: 4.5"
D'UNE COLONNE D'EAU (GN)
MAX. SUPPLY PRESSURE: 7" W.C. (NG)
PRESSION D'ALIMENTATION MAX: 7"
D'UNE COLONNE D'EAU (GN)
AFUE: 64%
FOR USE WITH GLASS DOORS CERTIFIED
WITH THIS UNIT ONLY.
WARNING: DO NOT ADD ANY MATERIAL TO
THE APPLIANCE, WHICH WILL COME IN
CONTACT WITH THE FLAMES, OTHER THAN
THAT SUPPLIED BY THE MANUFACTURER
WITH THE APPLIANCE.
ELECTRICAL RATING: 115V 1.5AMP 60HZ
THE APPLIANCE MUST BE VENTED USING
THE APPROPRIATE WOLF STEEL VENT
KITS. SEE OWNERS INSTALLATION MANUAL
FOR VENTING SPECIFICS. MINIMUM AND
MAXIMUM VERTICAL VENT LENGTHS ARE 3
FEET AND 40 FEET RESPECTIVELY.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE. ONTARIO L4M 0G8 CANADA
This illustration is for referece only. Refer to the rating plate on the appliance for accurate information.
MATERIAL: CLASS IIIA-2 PERMANENT LABEL, WATERPROOF, 10 MIL VELVET GLOSS LEXAN
note:
HOLE TO BE 0.250"Ø
BLACK ON WHITE BACKGROUND
The rating plate must remain with the appliance at all times. It must not be removed.
MAX OVERALL DECAL SIZE: 8.5"x4.75"
SERIAL NUMBERS TO BE ASCENDING FROM GDS25/CDVS25007100
1.4

mobile home installation

WOLF STEEL LTD.
This appliance must be installed in accordance with the manufacturer's instructions and the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home
TITLE: RATING PLATE,. GDS25 (SB)
Standard, CAN/CSA Z240 MH Series, in Canada. This appliance is only for use with the type(s) of gas
REVISION: A: UPDATED CSA YEAR & DESCRIPTION || 08.16.17_C.L.
indicated on the rating plate.
This mobile/manufactured home listed appliance comes factory equipped with a means to secure the appliance. Built
in appliances are equipped with 1/4" (6.4mm) diameter holes located in the front left and right corners of the base.
Use appropriate fasteners, inserted through the holes in the base to secure. For free standing products contact your
local authorized dealer / distributor for the appropriate securing kit. For mobile home installations, the appliance must
be fastened in place. It is recommended that the appliance be secured in all installations. Always turn off the pilot and
the fuel supply at the source, prior to moving the mobile home. After moving the mobile home and prior to lighting the
appliance, ensure that the logs are positioned correctly.
This appliance is certifi ed to be installed in an aftermarket permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases, unless a certifi ed kit is used.
Conversion Kits
This appliance is fi eld convertible between Natural Gas (NG) and Propane (P).
To convert from one gas to another, consult your Authorized dealer/distributor.
note:
Conversion kits are not available for Vent Free appliances.
8
W415-2207 / B / 02.05.18
9700539 (WSL)
4001658 (NAC)
GDS25N
0-2000ft
2000-4500ft
24,500 BTU/h
22,000 BTU/h
19,000 BTU/h
16,000 BTU/h
NOT FOR USE WITH SOLID FUEL
MINIMUM AND MAXIMUM HORIZONTAL
VENT LENGTHS ARE 10 INCHES AND 20
FEET RESPECTIVELY. PROPER REINSTAL-
LATION AND RESEALING IS NECESSARY
AFTER SERVICING THE VENT-AIR INTAKE
SYSTEM.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL:
A
4"
B
2"
C
2"
VENT TOP
2"
VENT BOTTOM
1"
VENT SIDES
HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE SALLE DE BAIN ET
UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON
INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE
MAISONS MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS
DE LA NORME DE SECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREES,
TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT
ETRE APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE DE MESURES DE
SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS
MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A. POUR UNE
UTILISER AVEC BARRIÈRE W010-3295. SUIVEZ LES INSTRUCTIONS D'INSTALLATION
4001657 (NGZ)
4001659 (WUSA)
GDS25P
MODEL
ALTITUDE / ELEVATION
0-2000ft
INPUT / ALIMENTATION
23,000 BTU/h
REDUCED INPUT /
16,000 BTU/h
ALIMENTATION REDUITE
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE
UTILSE AVEC CET APPAREIL
UTILISER AVEC LES PORTES VITREES
HOMOLOGUEES SEULEMENT AVEC CETTE
UNITE.
AVERTISSEMENT: N'AJOUTEZ PAS A CET
APPAREIL AUCUN MATERIAU DEVANT
ENTRER EN CONTACT AVEC LES FLAMMES
AUTRE QUE CELUI QUI EST FOURNI AVEC
CET APPAREIL PAR LE FABRICANT.
CLASS.: 115V 1.5AMP 60HZ L'APPAREIL
DOIT EVACUER SES GAZ EN UTILISANT
L'ENSEMBLE D'EVACUATION PROPRE A
WOLF STEEL. REFERER AU MANUEL
D'INSTALLATION DE PROPRIETAIRE POUR
TO CEILING FROM
L'EVACUATION PRECISE. LES LONGUEURS
STOVE TOP
48"
VERTICALES MINIMALES ET MAXIMALES
1"
SONT3 PIEDS ET 40 PIEDS
RESPECTIVEMENT.
SERIAL NUMBER / NO. DESERIE
SE TROUVENT DANS LE MANUEL D'INSTALLATION.
MANIFOLD PRESSURE: 10" W.C. (LP)
PRESSION AU COLLECTEUR: 10" D'UNE
COLONNE D'EAU(P)
MIN SUPPLY PRESSURE: 11" W.C.(LP)
2000-4500ft
PRESSION D'ALIMENTATION MIN: 11"
20,000 BTU/h
D'UNE COLONNE D'EAU (P)
MAX. SUPPLY PRESSURE: 13" W.C. (LP)
14,000 BTU/h
PRESSION D'ALIMENTATION MAX: 13"
D'UNE COLONNE D'EAU (P)
LES LONGUEURS HORIZONTALES MINIMALES ET
MAXIMALES SONT 10 POUCES ET 20 PIEDS
RESPECTIVEMENT.
IL EST IMPORTANT DE BIEN REINSTALLER ET
RESCELLER L'EVENT APRES AVOIR ASSURE LE
MAINTIEN DU SYSTEME DE PRISE D'AIR.
DEGAGEMENTS MINIMAUX DES MATERIAUX
COMBUSTIBLES:
A
4"
B
2"
C
2"
EVENT SUPERIEUR
2"
ENTRE LE DESSUS
DU FOYER
EVENT INFERIEUR
1"
ET LE PLAFOND
COTES DE L'EVENT
1"
GDS25
W385-1962 / A
20.1
AFUE: 64%
48"
PAGE 1 OF 2
DWG#: W385-1962
DATE: 06.11.14

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bayfield gds25p-1Bayfield gds25-1

Table of Contents