Vertical Through Existing Chimney - Napoleon Knightsbridge GDS60-1N Installation And Operation Manual

Table of Contents

Advertisement

Available languages

Available languages

installation
EN
4.3

vertical through existing chimney

WARNING
!
Risk of fi re.
Co-axial to co-linear venting confi gurations must only be used in a non-combustible chimney or enclosure.
Installation in a combustible enclosure could result in a fi re.
This appliance is designed to be attached to a 3" (76.2mm) co-linear aluminum fl ex vent system running the full
length of a masonry chimney.
The fl ex liners accommodate any contours of a
masonry chimney, however, it is necessary to keep
the fl exible liners as straight as possible. The inlet
air collar of the termination cap must be connected
to the air intake fl ex liner and the exhaust collar
must be connected to the exhaust fl exible liner.
Both Simpson Duravent and Selkirk co-linear to
co-axial adaptors have been approved on this
appliance
note:
A vent adaptor will be required directly off the appliance.
Follow vent manufacturer's installation instructions.
Different manufacturer's venting
components must not be combined.
Once the preferred manufacturer's
appliance adaptor has been attached, the
remainder of the system must be that of
the same manufacturer.
The only exception to this rule is to use
Wolf Steel's approved 3" (76.2mm) fl ex
liner and co-linear termination.
* Measured from appliance fl ue collar
to termination fl ue collar
30
W415-1328 / C / 12.06.18
AIR
INTAKE
TERMINATION
EXHAUST
FLUE
FLEX
LINER
*
40 FT (12.2m)
MAX.
10 FT (3.1m)
MIN
COAXIAL TO
CO-LINEAR
ADAPATOR
APPLIANCE
VENT ADAPTOR

Advertisement