INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: ANSI Z21.88, CSA 2.33 FOR VENTED GAS FIREPLACE HEATERS.
GDS20N

NATURAL GAS

GDS20P
PROPANE
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.

SAFETY INFORMATION

WARNING
!
If the information in these instructions are
not followed exactly, a fi re or explosion
may result causing property damage,
personal injury or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by a
qualifi ed installer, service agency or the supplier.
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com
$10.00
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
INSTALLATION AND
1.22
W415-0496 / D / 11.05.10
1

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon Arlington GDS20N

  • Page 1: Natural Gas

    INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE. INSTALLATION AND OPERATING INSTRUCTIONS CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: ANSI Z21.88, CSA 2.33 FOR VENTED GAS FIREPLACE HEATERS. GDS20N NATURAL GAS GDS20P PROPANE CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS. SAFETY INFORMATION WARNING If the information in these instructions are...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INSTALLATION OVERVIEW INTRODUCTION DIMENSIONS GENERAL INSTRUCTIONS GENERAL INFORMATION RATING PLATE INFORMATION VENTING VENTING LENGTHS AND COMPONENTS TYPICAL VENT INSTALLATION SPECIAL VENT INSTALLATIONS 3.3.1 PERISCOPE TERMINATION 3.3.2 CORNER TERMINATION VENT TERMINAL CLEARANCES DEFINITIONS ELBOW VENT LENGTH VALUES TOP EXIT HORIZONTAL TERMINATION VERTICAL TERMINATION INSTALLATION WALL AND CEILING PROTECTION...
  • Page 3: Installation Overview

    1.0 INSTALLATION OVERVIEW Cast top, see “FINISHING - CAST FRONT INSTALLATION AND Venting, see “VENTING” section. REMOVAL” section. Blower, see “OPTIONAL BLOWER INSTALLATION” section. Door, see “FINISHING - GLASS DOOR INSTALLATION AND REMOVAL” section. Rating Plate, see “RATING PLATE INFORMATION” section. W415-0496 / D / 11.05.10...
  • Page 4: Introduction

    2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • ANY CHANGES TO THIS APPLIANCE OR IT’S CONTROLS CAN BE DANGEROUS AND IS PROHIBITED. • Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fi...
  • Page 5: Dimensions

    DIMENSIONS ” 4” DIA. 7” DIA. ” ” 24” ” GENERAL INSTRUCTIONS WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT, WITH THE GLASS DOOR OPENED OR REMOVED. PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE. PROVIDE ADEQUATE VENTILATION.
  • Page 6: General Information

    The installation must conform with local codes or, in We suggest that our gas absence of local codes, the National Gas and Propane hearth products be installed Installation Code CSA B149.1 in Canada, or the National and serviced by professionals Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United States.
  • Page 7: Rating Plate Information

    RATING PLATE INFORMATION CERTIFIED UNDER / HOMOLOGUE SELON LES NORMES: CSA 2.22b-2009, ANSI 21.50b-2009 VENTED GAS FIREPLACE / FOYER AU GAZ AVEC EVACUATION. CE / FOYER AU GAZ AVEC EVACUATI CE / FOYER AU GAZ AVEC EVACUATI THIS FIREPLACE USES AND REQUIRES A FAST ACTING THERMOCOUPLE. REPLACE ONLY CE FOYER UTILISE ET REQUIERT UN THERMOCOUPLE À...
  • Page 8: Venting

    3.0 VENTING WARNING RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE. IF VENTING IS INCLUDED WITH SPACERS THE VENT SYSTEM MUST BE SUPPORTED EVERY 3 FEET FOR BOTH VERTICAL AND HORIZONTAL RUNS. USE SUPPORTS OR EQUIVALENT NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE REQUIRED CLEARANCE FROM COMBUSTIBLES.
  • Page 9: Venting Lengths And Components

    VENTING LENGTHS AND COMPONENTS Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or Metal-Fab venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air terminal locations for either system are set out in this manual and must be adhered to. For Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent and Metal-Fab follow the installation procedure provided with the venting components.
  • Page 10: Typical Vent Installation

    TYPICAL VENT INSTALLATION 16" MINIMUM 40 FT MAXIMUM 3 FT MINIMUM 24" MAXIMUM 25 3/8" 25 3/8" MINIMUM PLUS RISE* * See "VENTING" section W415-0496 / D / 11.05.10...
  • Page 11: Special Vent Installations

    SPECIAL VENT INSTALLATIONS 3.3.1 PERISCOPE TERMINATION Use the periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a 12" MIN minimum of 12” above grade. The maximum allowable vent length is 10’. TO GRADE 24"...
  • Page 12: Vent Terminal Clearances

    VENT TERMINAL CLEARANCES COVERED BALCONY APPLICATIONS ††* = 3 feet = 2 x ACTUAL feet INSTALLATIONS CANADA U.S.A. 12” 12” Clearance above grade, veranda porch, deck or balcony. 12” 9” Clearance to windows or doors that open. Δ Δ 12” * 12”...
  • Page 13: Definitions

    DEFINITIONS For the following symbols used in the venting calculations and examples are: > - greater than > - equal to or greater than < - less than < - equal to or less than - total of both horizontal vent lengths (Hr) and offsets (Ho) in feet - combined horizontal vent lengths in feet - offset factor: .03 (total degrees of offset - 135°*) in feet - combined vertical vent lengths in feet...
  • Page 14: Top Exit Horizontal Termination

    TOP EXIT HORIZONTAL TERMINATION ) < (V See graph to determine the required vertical Simple venting confi guration (only one 45° and 90° rise V for the required horizontal run H elbow) REQUIRED VERTICAL RISE IN FEET V 12.5 17.5 HORIZONTAL VENT RUN PLUS OFFSET IN FEET H The shaded area within the lines represents...
  • Page 15 ) > (V See graph to determine the required vertical Simple venting confi guration (only one 45° and 90° rise V for the required horizontal run H elbow) 147” REQUIRED VERTICAL RISE IN INCHES V 57” 12.5’ HORIZONTAL VENT RUN PLUS OFFSET IN FEET H The shaded area within the lines represents acceptable values for H...
  • Page 16: Vertical Termination

    VERTICAL TERMINATION ) < (V Simple venting configurations. See graph to determine the required vertical rise V for the required horizontal run H REQUIRED VERTICAL RISE IN FEET V HORIZONTAL VENT RUN PLUS OFFSET IN FEET H The shaded area within the lines represents acceptable values for H and V For vent configurations requiring more than one 45°...
  • Page 17 ) > (V Simple venting configurations. See graph to determine the required vertical rise V for the required horizontal run H REQUIRED VERTICAL RISE IN FEET V HORIZONTAL VENT RUN PLUS OFFSET IN FEET H The shaded area within the lines represents acceptable values for H and V For vent configurations requiring more than one 45°...
  • Page 18: Installation

    4.0 INSTALLATION WARNING FOR SAFE AND PROPER OPERATION OF THE APPLIANCE, FOLLOW THE VENTING INSTRUCTIONS EXACTLY. ALL INNER EXHAUST AND OUTER INTAKE VENT PIPE JOINTS MAY BE SEALED USING EITHER RED RTV HIGH TEMP SILICONE SEALANT W573-0002 (NOT SUPPLIED) OR BLACK HIGH TEMP MILL PAC W573-0007 (NOT SUPPLIED) WITH THE EXCEPTION OF THE APPLIANCE EXHAUST FLUE COLLAR WHICH MUST BE SEALED USING MILL PAC.
  • Page 19: Horizontal Installation

    4.1.1 HORIZONTAL INSTALLATION WARNING THE FIRESTOP ASSEMBLY MUST BE INSTALLED WITH THE VENT SHIELD TO THE TOP. TERMINALS MUST NOT BE RECESSED INTO A WALL OR SIDING MORE THAN THE DEPTH OF THE RETURN FLANGE OF THE MOUNTING PLATE. This application occurs when venting through an exterior wall. Having determined the correct height for the air terminal VENT location, cut and frame a hole in the exterior wall as...
  • Page 20: Appliance Vent Connection

    APPLIANCE VENT CONNECTION Attach the adjustable pipe to the last section of rigid pipe. Secure #8 X 1/2” with screws and seal. SELF DRILLING Install the inner fl ex pipe to the appliance. Secure with 3 screws SCREWS and fl at washers. Seal the joint and screw holes using the high temperature sealant W573-0007 (not supplied).
  • Page 21: Vertical Air Terminal Installation

    VERTICAL AIR TERMINAL INSTALLATION WARNING MAINTAIN A MINIMUM 2” SPACE BETWEEN THE AIR INLET BASE AND THE STORM COLLAR. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
  • Page 22: Gas Installation

    GAS INSTALLATION WARNING RISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCH AS SPARKS OR OPEN FLAMES. SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 23: Mobile Home Installation

    MOBILE HOME INSTALLATION This appliance is certifi ed to be installed as an OEM (Original Equipment Manufacturer) installation in a manufactured home or mobile home and must be installed in accordance with the manufacturer’s instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada.
  • Page 24: Finishing

    5.0 FINISHING CAST FRONT INSTALLATION AND REMOVAL Lift the top cast piece off of the appliance. SCREWS BRACKET FRONT Detach the front cast piece from the side pieces by removing the screws from the brackets located in the upper inside corner. Slide the front straight up to remove.
  • Page 25: Log Placement

    LOG PLACEMENT WARNING FAILURE TO POSITION THE LOGS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY LOGS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY. LOGS MUST BE PLACED IN THEIR EXACT LOCATION IN THE APPLIANCE. DO NOT MODIFY THE PROPER LOG POSITIONS, SINCE APPLIANCE MAY NOT FUNCTION PROPERLY AND DELAYED IGNITION MAY OCCUR.
  • Page 26: Optional Blower Installation

    6.0 OPTIONAL BLOWER INSTALLATION BLOWER Cut and remove the tie securing the blower switch wires to the heat shield. Connect the white wire coming from below the appliance to the terminal on the blower. Connect the black blower wire to the black wire coming from below the appliance.
  • Page 27: Operation

    7.0 OPERATION The on/off switch is located on the back of the appliance at the top right corner on model GDS20. WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 28: Adjustments

    8.0 ADJUSTMENTS PILOT BURNER ADJUSTMENT Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise PILOT direction to reduce the gas fl ow. BURNER THERMOPILE Inlet pressure can be checked by turning screw (A) THERMOCOUPLE counter-clockwise until loosened and then placing pressure gauge tubing over the test point.
  • Page 29: Flame Characteristics

    FLAME CHARACTERISTICS It’s important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the illustrations provided. If any fl ames 3/8” - 1/2” appear abnormal call a service person. FLAME MUST ENVELOPE UPPER 3/8"...
  • Page 30: Maintenance

    9.0 MAINTENANCE MAINTENANCE MAINTENANCE WARNING MAINTENANCE TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
  • Page 31: Orifice Replacement

    ORIFICE REPLACEMENT Remove the cast front and the door, see "GLASS DOOR / CAST FRONT INSTALLATION AND REMOVAL" section in the Finishing section of this manual. Remove the 2 securing screws indicated and remove the burner assembly. The orifi ce is located on the left hand side. Reinstall the burner ensuring that the venturi tube fi...
  • Page 32: Replacements

    10.0 REPLACEMENTS WARNING FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY. ** THIS IS A FAST ACTING THERMOCOUPLE. IT IS AN INTEGRAL SAFETY COMPONENT. REPLACE ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
  • Page 33 TERMINAL KITS REF NO. PART NO. DESCRIPTION GD-175 - WALL TERMINAL KIT BM6790 90° ELBOW - 7" DIAMETER GD-222 TERMINAL ASSEMBLY BM67ADJ 30" TO 53" ADJUSTABLE PIPE - 7" DIA W010-1313 FIRESTOP SPACER W585-0267 TOP VENT SHIELD W020-0032 HARDWARE BM3730 BLACK TRIM COLLAR BM6724 24"...
  • Page 34 ACCESSORIES REF NO. PART NO. DESCRIPTION W660-0081 MILLIVOLT THERMOSTAT REMOTE CONTROL - ADVANTAGE PLUS GS-65KT BLOWER KIT GDSLL-KT LEG LEVELLING KIT W175-0234 CONVERSION KIT - NG-LP W175-0237 CONVERSION KIT - LP-NG BM6745 45° ELBOW GD-301 HEAT GUARD W025-0001 DECORATIVE BRASS BAND GS-331S STOVE TOP INSET - SOAPSTONE GS-331F...
  • Page 35 W415-0496 / D / 11.05.10...
  • Page 36: Trouble Shooting

    11.0 TROUBLE SHOOTING WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS.
  • Page 37 SYMPTOM PROBLEM TEST SOLUTION Pilot will not light. No spark at pilot burner. Check if pilot can be lit by a match. Check that the wire is connected to the push button igniter. Check if the push button igniter needs tightening. Replace the wire if the wire insulation is broken or frayed.
  • Page 38: Warranty

    12.0 WARRANTY NAPOLEON® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2008 Quality Assurance Certifi cate. NAPOLEON® products are designed with superior components and materials assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fi red at a quality test station. The complete appliance is again thoroughly inspected by a qualifi...
  • Page 39: Service History

    13.0 SERVICE HISTORY 43.1 W415-0496 / D / 11.05.10...
  • Page 40 14.0 NOTES 44.1 W415-0496 / D / 11.05.10...