7.11 Maintenance box information
Structure
Parameter total counter
Parameter counter for 1
maintenance box
Parameter
Information of the maintenance box are shown in this field.
The parameter < Maintenance box information > is n bytes binary code that indicates the state and reset count of the each
maintenance box.
For these printers, the number of maintenance box of the parameter is one for a fixed waste ink pad.
Item
Maintenance box status
Maintenance box reset count
7.12 Serial No. information
Structure
Parameter counter
Parameter
The parameter < Serial No. information > is ten byte Binary codes that indicates the machine identification information like
Serial No.
Revision: 1
Item
Byte(Hex)
Header
Byte
1
1
Item
Byte(Hex)
Header
0Ah
Value(Hex)
1
1
1
4
Maintenance box information
(2bytes * maintenance box count)
explanation
0 : not full
1 : near full
2 : full
0-255 (counter)
Value(Hex)
1
1
Serial No. Information
37h
3
02h
40H
0AH
2013/12/18
Page: 85