Denied Counter
Absent Counter
Invalid Signature Counter: 0
The following table describes the fields shown in the display:
Fi el d
Power
Nominal Power
Consumed Power
Usage Threshold
Traps
Port
Powered device
Admin State
Priority
Oper State
Classification
Overload Counter
Short Counter
Denied Counter
Absent Counter
Invalid Signature Counter
Des cri pti o n
The inline power sourcing equipment operational status.
The inline power sourcing equipment nominal power in Watts.
Measured usage power in Watts.
The usage threshold expressed in a percentage for comparing the measured
power and initiating an alarm if the threshold is exceeded.
Indicates if inline power traps are enabled.
The Ethernet port number.
A description of the powered device type.
Indicates if the port is enabled to provide power. It can be Auto or Never.
The priority of the port from the point of view of inline power management. It can
be Critical, High or Low.
Describes the inline power operational state of the port. It can be On, Off, Test-
Fail, Testing, Searching or Fault.
Power consumption classification of the powered device.
Counts the number of overload conditions that has been detected.
Counts the number of short conditions that has been detected.
Counts the number of times power has been denied.
Counts the number of times power has been removed because powered device
dropout was detected.
Counts the number of times an invalid signature of a powered device was
detected.