Chapter 3
Installation Procedures
Figure 33: Detail of Wrapped Connectors
WARNING!
Assembly without waterproof sealing tape or removing the waterproof sealing tape from this device
voids its warranty.
Section 3.6
Hazardous Location Information
The following is the hazardous location information for this equipment:
nA IIC T4 GC X II 3G
Rating: 48VDC,4A
Class I Division 2 Groups A,B,C,D
T4
Section 3.7
Hazardous Location Installation
Hazardous Location Considerations
This equipment is suitable for use in Class 1, Division 2, Groups A, B, C, D or non-hazardous locations only. The
following ATTENTION statement applies to use in hazardous locations.
WARNING!
EXPLOSION HAZARD
• Substitution of components may impair suitability for Class I, Division 2
• Do not disconnect equipment unless power has been switched off or the area is known to be non-
hazardous.
34
RUGGEDCOM WIN7000
Installation Guide
Hazardous Location Information