Specification

A direct vent inbuilt gas fireplace with a glass front and convection fan, pushing warm air from the
top of the appliance. Operated by a simple infra-red remote or by the Rinnai Wi-Fi app that allows
full thermostatic control, as well as other features such as timers. Different burn media and frame
options are available.
Ember 600 specification summary
Input
= 12-23 MJ/h
Output
= 2.5-5.0* kW
Efficiency
= 77% (on high)
Heating area = up to 85 m
Gas type
= NG or ULPG
Ember 700 specification summary
Input
= 14-27 MJ/h
Output
= 3-6.0* kW
Efficiency
= 77% (on high)
Heating area = up to 99 m
Gas type
= NG or ULPG
* Will vary according to gas type and flue configuration.
** Will vary depending on geographical location in NZ.
Suitability
Suitable for masonry installations and
installations into a mock chimney, in open plan
areas and living rooms.
Data plate
Located on the lower RHS of the base panel in
front of the gas control.
Convection fan
120 V AC 50 Hz 2-speed centrifugal blower.
Lighting
Halogen lamps 240 V 25 W x 2.
Gas connection
Brass ½ " BSPT male fitting, the gas supply
terminates inside the heater—lower right hand
side of the appliance.
Ignition
230-240 V AC 50 Hz high voltage electronic
spark generation unit.
Installation considerations
Room size—smaller rooms will heat up quickly,
and due to the efficiency of the appliance, the
Ember will turn to a low flame setting once the
set temperature has been reached.
**
2
**
2
For efficient performance Rinnai recommends
installing the fire as close to the floor as
possible. If the unit is installed higher up the
wall the movement of air from the convection
fan, depending on the room configuration,
could create draughts.
Noise
level: 37-45 dB(A)
Flueing: Masonry
Colinear flexi flue, air intake Ø 75 mm, exhaust
Ø 100 mm. Appliance must be installed with a
Rinnai Ember flue system.
Flueing: Mock chimney
Colinear (air intake Ø 75 mm, exhaust Ø 100
mm) to coaxial direct vent flueing (inner Ø 100
mm, outer Ø 170 mm). Appliance must be
installed with a Rinnai Ember flue system.
Electrical
This heater has a 1.5 m power cord with a
three pin plug supplied. The power cord passes
through a slot in the back left hand corner of
the appliance.
High
= 110 W
Standby
= <1W
Safety devices
Flame failure sensing system, pressure relief,
overheat safety switch, air temperature sensor,
thermal fuse, overcurrent fuse, and spark
detector.
Temperature control
Operated by using the basic infra-red remote*,
or for more features, such as timers and
thermostatic control, using Rinnai's Wi-Fi
fireplace controller app.
* Temperature sensor is located in the bottom
of the remote
Weights
Ember 600
Ember 700
51 kg