Horizontal wall terminal
(R3650)
Aluminium flue terminal
required for all horizontal
terminations.
Depth with horizontal flashing
kit installed—252 mm.
Flue elbow 45° (R3642)
Kit contains two 45° bends.
Offsets obstructions. Elbow
swivels 360 ° at base. Angle not
adjustable.
Once joined effective length
reduces 35 mm to approx. 73 mm.
Inner:
Aluminium
Outer:
Galvanised steel
Horizontal flashing kit
(R3646)
Flashing components used
to join the internal flue to the
outside flue—to provide a
weathertight seal in horizontal
flue installations. Refer
horizontal wall terminal for
installed dimensions. Box
depth is 100 mm.
340 mm
11715 flashing box
11716 flashing collar
Ø 175 mm
270 mm
Offset
Flue pipe (length and code)
None (bend to bend)
150 mm
230 mm
300 mm
450 mm
600 mm
900 mm
1200 mm
Elbow flue strap (R3644)
Flue support for elbows and
offsets.
Rise
Offset
N/A
124 mm
R3630
203 mm
R3631
257 mm
R3632
311 mm
R3633
417 mm
R3634
524 mm
R3635
737 mm
R3636
949 mm
Ember Installation Guide: 12890-F 06-21 | 39
Rise
340 mm
419 mm
473 mm
527 mm
633 mm
740 mm
953 mm
1165 mm