Network and signal diagnostic messages (NWSxxx)

NWS620
Express output queue full, CPU can not send the message to the MISP.
NWS621
MISP output buffer not available.
NWS622
Message cannot be sent to the MISP because of invalid message or
conditions.
NWS623
Message cannot be sent to a line card.
NWS624
Shelf contains at least one ISDN BRI card, wait about 45 seconds to enable
the loop.
NWS625
Database error. Database protected pointer is nil.
NWS626
Self test command only applies to the MISP network cards and ISDN BRI
line cards. Make sure you specify correct card.
NWS627
Self test can only be invoked if card is disabled.
NWS628
Self test can only be invoked if line card is disabled.
NWS630
Card slot is unequipped.
NWS631
Card slot does not respond.
NWS632
Self test failed.
NWS633
MISP status is undefined.
NWS635
Line card does not respond.