Inspecting The Facepiece; Inspecting The Air Control Valves; Storage; Troubleshooting - 3M SA-1500 User Instructions

Dual airline supplied air respirators
Table of Contents

Advertisement

Available languages

Available languages

4. Do not use detergents which contain lanolin or other oils since they may soften and/or distort the facepiece lens.
5. Rinse in clean water. Water temperature should not exceed 120°F (49°C).
6. Dry in uncontaminated ambient air. If using forced air, do not exceed 120°F (49°C).
7. Disinfect facepiece by soaking in a solution of quaternary ammonia disinfectant or sodium hypochloride
(1 oz [30 ML] household bleach in 2 gallons [7.5 L] of water), or other disinfectant. Rinse in fresh, warm water and air
dry in non-contaminated atmosphere.

Inspecting the Facepiece

This respirator must be inspected before each use to ensure it is in good operating condition. Any damaged or defective
parts must be replaced before use. The following procedure is suggested:
1. Check the facepiece and breathing tube for cracks, tears and dirt. Be certain the facepiece, especially the faceseal area,
is not distorted. The material must be pliable, not stiff.
2. Make sure that head straps are intact and have good elasticity.
3. Examine all plastic parts for signs of cracking or fatiguing.
4. Remove the exhalation valve cover and examine the valve and valve seat for signs of dirt, distortion, cracking or tearing.
Snap the exhalation valve cover back into place.
5. Examine the bayonet lugs for signs of unusual wear. Examine the orange gasket for signs of wear.
6. Repair or replace parts only with the 3M components approved for this system.

Inspecting the Air Control Valves

The regulators and connectors have no moving parts except for the airfl ow adjustment knob on the 3M™ Air Regulator
SA-1009, so there is very little that will require maintenance. If the air from the compressor or pump meets regulatory
requirements, the spring check valve inside of these regulators and connectors should continue to operate normally for a
long period of time. It is recommended that you follow these maintenance guidelines for the 3M air regulator SA-1009 and
3M™ Low Pressure Connector SA-1029:
1. Waist belt (GVP-127) - The waist belt may be hand laundered with mild detergent, a clean water rinse and air dried.
2. Air regulator (SA-1009) and low pressure connector (SA-1029) – Clean the exterior of the valve or connector as needed
by wiping down with a damp cloth. Blow clean with compressed air.
Do not immerse the air regulator or low pressure connector in water; doing so may saturate the foam spring valve with
water. Failure to dry the foam may result in the growth of mold or mildew.

Storage

The respirator should be placed in a clean container or bag and stored at ambient temperature in a dry, uncontaminated area
protected from bright sunlight.

TROUBLESHOOTING

Use the table below to help identify possible causes and corrective action for problems you may experience.
Problem
Possible Cause
You smell or taste contaminants or
Equipment malfunction
irritation occurs,
Incorrect assembly
or breathing becomes diffi cult
Misuse
or dizziness or other distress occurs
Pressure not within manufacturer's
guidelines
Decrease or loss of airfl ow
Supplied air hose is kinked, split or
restricted
Breathing tube disconnected at the
facepiece or at air control valve
Supplied air hose disconnected at air
control valve or fi lter and regulator panel
Decrease in pressure at fi lter and
regulator panel
Breathing tube cracks or ruptures
Contact with organic solvents
CAUTION
Corrective Action
Leave the work area immediately
and notify your supervisor. Do not
use the dual airline system until the
performance check in the Assembly
Section of this User Instruction is
completed and the equipment is
checked by your supervisor.
If using the combination dual airline
breathing tubes in air purifying mode,
replace the cartridges or fi lters
Remove kink or equipment that may
have rolled onto the hose. Replace
hose if cut or split.
Ensure breathing tube is connected
Inspect and reconnect hose fi ttings
Check pressure and readjust to
required pressure based upon hose
length and 3M™ Air Control Valve
SA-1009 or SA-1029 used
Replace old, dirty fi lter(s) in fi lter
and regulating panel that could be
restricting airfl ow
Clean only with warm water and mild
detergent
15

IMPORTANT NOTICE

WARRANTY: In the event any 3M PSD product is found to be defective in material, workmanship, or not in conformation
with any express warranty for a specifi c purpose, 3M's only obligation and your exclusive remedy shall be, at 3M's option, to
repair, replace or refund the purchase price of such parts or products upon timely notifi cation thereof and substantiation that
the product has been stored, maintained and used in accordance with 3M's written instructions.
EXCLUSIONS TO WARRANTY: THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY IMPLIED WARRANTY OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OTHER WARRANTY OF QUALITY, EXCEPT OF TITLE AND
AGAINST PATENT INFRINGEMENT.
Limitation of Liability: Except as provided above, 3M shall not be liable or responsible for any loss or damage, whether
direct, indirect, incidental, special or consequential, arising out of sale, use or misuse of 3M PSD products, or the user's
inability to use such products. THE REMEDIES SET FORTH HEREIN ARE EXCLUSIVE.
FOR MORE INFORMATION
In United States, contact:
Website: www.3M.com/PPESafety
Technical Assistance: 1-800-243-4630
For other 3M products:
1-800-3M-HELPS or 1-651-737-6501
RENSEIGNEMENTS SUPPLÉMENTAIRES
Aux États-Unis :
Internet : www.3M.com/PPESafety
Assistance technique : 1 800 243-4630
Autres produits 3M :
1 800 364-3577 ou 1 651 737-6501
PARA MAYORES INFORMES
En Estados Unidos:
Sitio Web: www.3M.com/PPESafety
Soporte técnico: 1-800-243-4630
Para otros productos 3M:
1-800-3M-HELPS o 1-651-737-6501
PARA MAIS INFORMAÇÕES
Nos Estados Unidos, entre em contato com:
Website: www.3M.com/PPESafety
Assistência Técnica: 1-800-243-4630
Para outros produtos 3M:
1-800-3M-HELPS ou 1-651-737-6501
16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sa-2500

Table of Contents