Inspecting the Facepiece

Remove and keep the protective static cling label attached to the lens of a new facepiece; the label may be re-used
during storage of the facepiece.
The facepiece must be complete and in serviceable condition with no worn, loose, or damaged components. See the
main components of the facepiece in c.
AV-3000 HT
Figure 1-3 Facepiece components
To inspect the facepiece
1
Inspect the facepiece seal and other rubber components for deformation, wear, cracks, or other damage.
2 Inspect the lens and lens frame.
a Inspect the lens for scratches, gouges, cracks, crazing, distortion, melting, or any other damage or condition
that could impair the user's vision or the operation of the facepiece.
b Inspect the lens frame for damage such as cracks or distortion.
c Verify that the lens frame screws are present and installed correctly.
3 Inspect the head harness.
a Check that all harness anchors are present and operating properly.
b Inspect the head harness for correct installation with all straps oriented correctly.
c Inspect the head harness for damage or worn components.
4 Inspect the voicemitter ducts.
a Verify that the voicemitter ducts are properly installed.
b Inspect the voicemitters for damage and verify that the voicemitters are properly installed and secure in the
voicemitter ducts.
P/N 595360-01
Rev G
E-Z Flo+
Regulator
202004
INSPECTING THE RESPIRATOR COMPONENTS
Head Harness
Lens Frame
(Bezel)
Lens (Fenestra)
Nose cup with
inhalation valves
Voicemitter
E-Z-Flo C5
Regulator
VISION C5