LG MG200 Service Manual page 106

Table of Contents

Advertisement

Power Level
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
Procedure
a) Initialize phone by clicking Initialize button.
b) Set the BCH and TCH of the phone 190 for GSM850 and 661 for PCS1900. Of cause you
have to match test equipment's BCH and TCH ARFCN with this value. For each power level,
adjust the DAC value to get target power and click Test button. Then you can see the output
power displayed on test equipment.
c) Savign updated clibration data into phone by clicking Calib Saving button.
Table 6-2. Tx Target Powers
DCS [dBM]
GSM [dBM]
-
-
-
-
-
32
31
29
27
25
23
21
19
17
15
13
11
9
8
7
- 105 -
6. SERVICE AND CALIBRATION
PCS [dBM]
29
29
28
28
26
26
24
24
22
22
20
20
18
18
16
16
14
14
12
12
10
10
8
8
6
6
4
4
2
2
0
0
-
-
-
-
-
-
-
-

Advertisement

Table of Contents
loading

Table of Contents