11. Heat radiation data

When in use, all Fluidmesh gateway units and radio transceivers generate
heat as a by-product of electrical activity.
Heat radiated by a Fluidmesh device may be of concern in confined
locations such as server rooms (where the cumulative heat generated by
a collection of electrical and electronic devices may cause damage to
sensitive electronic components) and outdoor equipment enclosures (in
which electronic components may overheat if the enclosure is not properly
ventilated).
WARNING
The outer surfaces of some Fluidmesh units may become hot
during normal operation. Such units have a 'Hot Surfaces'
warning triangle on their outer enclosures.
During normal operation, do not touch or handle such unit
enclosures without personal protective equipment.
The following table shows nominal heat-radiation figures for all Fluidmesh
devices under idle conditions, and under full-load conditions.
All heat-radiation figures are given in British Thermal Units (BTU) per
hour.
Device
FM1000 Gateway
(model FM1000-
GWY)
FM10000 Gateway,
first and second
generations (model
FM10000-GWY)
FM Ponte kit (model
FMPONTE-50)
FM1200 Volo (model
FM1200V-HW)
All 3200-series
transceivers (models
FM3200 and
FM3200E-HW)
FM3500 Endo
(model FM3500)
FM4200 Mobi
(model FM4200)
© 2021 Cisco and/or its affiliates. All rights reserved.
Fiber-
Idle @
Idle @
optic
115 Vac /
230 Vac /
module
60 Hz
60 Hz
installed
25.590
33.780
271.595
267.159
6.479
6.138
6.479
6.138
10.230
10.230
9.889
9.889
10.230
10.230
Heat radiation data
Full load
Full load
@ 115
@ 230
Vac / 60
Vac / 60
Hz
Hz
25.250
33.100
436.395
437.078
19.778
19.437
19.778
19.437
24.552
24.552
26.939
26.939
24.552
24.552
Page 118 of 132