AIR CLEANER / CARBURETOR
METERING LEVER ADJUSTMENT
1. Install the metering body spring, inlet needle valve, metering
lever, metering lever pin, and the metering lever pin screw on
the pump body.
2. Measure the gap between the metering lever surface and the
pump body surface.
Specification
1.18 ~ 1.50 mm (0.046 ~ 0.059 in)
3. If the metering is outside the specification, adjust by bending
the metering lever.
5-10
METERING LEVER
PUMP BODY
HHT25S•HHT35S
1.18 ~ 1.50 mm
(0.046 ~ 0.059 in)