Zeitrelais H3DT
H3DT
H3DT-H
Characteristics
Accuracy of operating
time
Setting error
Influence of voltage
Influence of
temperature
Insulation resistance
Dielectric strength
Impulse withstand
test voltage
Noise immunity
Static immunity
Destruction
Vibration
resistance
Malfunction 0.5-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions
Destruction
Shock
resistance
Malfunction 100 m/s
Mechanical
Life
expectancy
Electrical
Degree of protection
Weight
Applicable standards
cULus: UL 508/CSA C22.2 No. 14
EN 61812-1: Pollution degree 2, Overvoltage category III
Safety
CCC: Pollution degree 2, Overvoltage category II, section GB 14048.5
standards
LR: Category ENV1.2
DNV GL *
(EMI)
Radiated Emissions:
Emission AC Mains:
Harmonic Current:
Voltage Fluctuations and Flicker:
(EMS)
EMC
Immunity ESD:
Immunity RF-interference:
Immunity Burst:
Immunity Surge:
Immunity Conducted Disturbance:
Immunity Voltage Dip/Interruption:
* Certification is pending for DNV GL.
I/O
Input
Output
Control output
26
Erstellt am 09.10.2020 um 23:38 Uhr | Alle Angaben ohne Gewähr, Irrtümer und Änderungen vorbehalten!
|
ATEG Automation GmbH
Intzestraße 50
1% of FS max. (1% 10 ms max. at 1.2-s range)
10% of FS 0.05 s max.
0.5% of FS max. (0.5% 10 ms max. at 1.2-s range)
2% of FS max. (2% 10 ms max. at 1.2-s range)
100 M min. at 500 VDC
Between charged metal part and operating section: 2,900 VAC 50/60 Hz for 1
min.
Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz for
1 min.
Between contacts not located next to each other: 1,000 VAC 50/60 Hz for 1 min.
Between power supply terminals: 1 kV for 24-VAC/DC and 48-VAC/DC models,
5 kV for all other models.
Between conductor terminal and operating section: 7.4 kV
Square-wave noise generated by noise simulator (pulse width: 100 ns/1 s,
1-ns rise): 1.5 kV (between power supply terminals)
Malfunction: 4 kV, Destruction: 8 kV
0.75-mm single amplitude at 10 to 55 Hz for 2 h each in 3 directions
1,000 m/s
2
3 times each in 6 directions
2
3 times each in 6 directions
10 million operations min. (under no load at 1,800 operations/h)
100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h)
IP30 (Terminal block: IP20)
Approx. 90 g
EN 61812-1
EN 55011 class B
EN 55011 class B
EN 61000-3-2
EN 61000-3-3
EN 61812-1
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-11
None
The Timer operates as soon as the Timer is turned ON. The Timer
starts timing when the power is turned OFF and the output is turned
OFF when the time set on the dial elapses.
|
42859 Remscheid
Installation Pitch and Output
Switching Capacity (Reference
Values)
The relation between the installation pitch
and the load current is shown in the following
graph.
If Timer is used under load conditions that
exceed the specified values, the temperature
inside the Timer will increase, reducing the
life expectancy of internal parts.
80
70
60
50
40
30
20
10
0
Testing Method
Tested Timer: H3DT-H
Applied voltage: 240 VAC
Installation pitch: 0 and 10 mm
Load current: 5 A
Test
timer
1
DIN Track
|
|
Germany
Tel.: +49 (0)2191 / 591457-0
5
10
15
20
25
30
Mounting interval (mm)
Test
Test
Test
Test
timer
timer
timer
timer
2
3
4
5
Timer installation pitch: d
Seite 27 von 37
|