Vertical Terminations - Regency ACC40LENG Owners & Installation Manual

Zero clearance direct flue gas fireplace, city series
Hide thumbs Also See for ACC40LENG:
Table of Contents

Advertisement

installation

Vertical Terminations

Rigid Pipe 102mm x 175mm
The minimum components required for a basic vertical
termination are:
1
Vertical Termination Cap
1
Rigid Pipe Adaptor (510-994)
1
Ceiling Firestop
1
Flashing
1
Storm Collar
1
Length of pipe to suit wall thickness
(see chart)
Galvanized pipe is desirable above the roofline due to its higher
corrosion resistance. Continue to add pipe sections through the
flashing until the height of the flue cap meets the minimum height
requirements specified in diagram 2 or local codes. Note that for
steep roof pitches, the vertical height must be increased. A poor
draft, or down drafting can result from high wind conditions near
big trees or adjoining roof lines, in these cases, increasing the flue
height may solve the problem.
Roof Pitch
Meters
flat to 7/12
over 7/12 to 8/12
over 8/12 to 9/12
over 9/12 to 10/12
over 10/12 to 11/12
over 11/12 to 12/12
over 12/12 to 14/12
over 14/12 to 16/12
over 16/12 to 18/12
over 18/12 to 20/12
over 20/12 to 21/12
WARNING:
Do not combine venting components from different venting systems.
Use of the the AstroCap
and FPI Riser is acceptable with all systems.
TM
This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction
with Duravent Direct-Flue, Selkirk Direct-Temp, Ameri Flue Direct Venting, ICC Excel
Direct, Olympia Chimney, and Security Secure Flue systems. Use of these systems with
the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing
of components.
The FPI AstroCap
TM
and FPI Riser Flue terminal are certified for installations using FPI venting systems as well as Simpson Dura-Vent
Metal Products Ameri Flue Direct Flue, Security Secure Vent
mark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Flue are registered and/or proprietary trademarks of Simpson Dura-Flue Co. Inc.
| City Series ACC40E
44
0.61
0.61
0.61
0.76
0.99
1.22
1.52
1.83
2.13
2.29
2.44
, ICC Excel, Selkirk Direct-Temp and Olympia Chimney. AstroCap
®
Diagram 2
Diagram 1
When using Rigid Flue other than
Simpson Dura-Flue, 3 screws must be
used to secure rigid pipe to adaptor.
®
Direct Flue, American
is a proprietary trade-
TM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acc40lelpAcc40leulpgAcc40rengAcc40relpAcc40reulpg

Table of Contents